Я4С-89: Difference between revisions
Chrisjones (talk | contribs) No edit summary |
(Introduced 1978 according to https://eltesta.com/wp-content/uploads/2021/12/Alma_Mater_2021.pdf p.242) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{Plugin Sidebar | {{Plugin Sidebar | ||
|manufacturer=Vilnius Research | |||
summary=Pulse Generator | | |series=Soviet 7000-series clones | ||
image=Я4С-89_front.jpg | | |type=Я4С-89 | ||
caption=Я4С-89 front panel | |summary=Pulse Generator | ||
|image=Я4С-89_front.jpg | |||
introduced= | |caption=Я4С-89 front panel | ||
discontinued=(?) | | |introduced=1978 | ||
manuals= | |discontinued=(?) | ||
|designers= | |||
|manuals= | |||
* ''please add'' [[Category:Manual needed]] | * ''please add'' [[Category:Manual needed]] | ||
}} | }} | ||
The '''Я4С-89''' is a plug-in for [[Soviet 7000-series clones]] which contains a pulse generator. | The '''Я4С-89''' is a plug-in for [[Soviet 7000-series clones]] which contains a pulse generator. | ||
It is intended for use with the sampling plugins in a similar manner to the Tek [[S-52]] pulse | It is intended for use with the sampling plugins in a similar manner to the Tek [[S-52]] pulse | ||
Line 39: | Line 40: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Period | | {{Spec | Period | 10 μs to approx 15 ms, or external trigger }} | ||
{{Spec | Post-trigger delay | 0 to approx 400 ns }} | {{Spec | Post-trigger delay | 0 to approx 400 ns }} | ||
{{Spec | Rise time | Depends on external pulse shaper }} | {{Spec | Rise time | Depends on external pulse shaper }} | ||
Line 57: | Line 58: | ||
Я4С-89_pulse_outputs.jpg | Top trace trigger output, bottom trace + pulse output, pulse length set to 10ns. Note initial positive bump to trigger tunnel diode, then big negative spike 10ns later to switch it off. | Я4С-89_pulse_outputs.jpg | Top trace trigger output, bottom trace + pulse output, pulse length set to 10ns. Note initial positive bump to trigger tunnel diode, then big negative spike 10ns later to switch it off. | ||
</gallery> | </gallery> | ||
[[Category:Soviet 7000-series clones]] | |||
[[Category:Vilnius Research Institute products]] |
Latest revision as of 09:00, 21 February 2022
The Я4С-89 is a plug-in for Soviet 7000-series clones which contains a pulse generator. It is intended for use with the sampling plugins in a similar manner to the Tek S-52 pulse generator head. It can free-run or take a 5 V external trigger signal.
The pulse outputs require an external pulse shaping cable in order to be useful. The cables contain a 1И308К 50 mA tunnel diode.
From the top, the connectors are:
- external 5 V (TTL) trigger in
- sync output, variable level and polarity
- positive-going pulse output
- negative-going pulse output
The buttons are:
- manual trigger
- external trigger mode
- period 1/0.1/0.01 ms
- delay 25/50/100/200 ns (can be added by pressing multiple buttons)
- pulse width 0.01/0.2 μs
The rotary controls are:
- external trigger level
- period vernier
- sync output amplitude, negative-zero-positive
- delay vernier
- pulse width
then two screwdriver bias adjustments for the positive-going and negative-going pulse outputs.
The connectors are СР50-73 type, which are almost compatible with BNC connectors but the latch is a tight fit and the centre contact can be unreliable.
Key Specifications
Period | 10 μs to approx 15 ms, or external trigger |
---|---|
Post-trigger delay | 0 to approx 400 ns |
Rise time | Depends on external pulse shaper |
Pulse width | 10 ns to 10 μs in two ranges |
Trigger output amplitude | −5 V to +5 V into 1 MΩ, −1 V to +1 V into 50 Ω |
Pulse output amplitude | 200 mV or 400 mV depending on pulse shaper |
Links
Pictures
-
Front
-
Threequarter view
-
Pulse shaper cables schematic
-
Top trace trigger output, bottom trace + pulse output, pulse length set to 10ns. Note initial positive bump to trigger tunnel diode, then big negative spike 10ns later to switch it off.