035-5031-00: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary Tags: Mobile edit Mobile web edit |
||
(7 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
{{TM500 | mfg=Tektronix | type=035-5031-00 | class=special function | function=delay line | image= | {{TM500 | ||
manuals= | |mfg=Tektronix | ||
* [[Media:061-1427-00.pdf|Tektronix 035-5031-00 Manual ( | |type=035-5031-00 | ||
|class=special function | |||
|function=delay line | |||
|image=Tek 035-5031-00 1.jpg | |||
|introduced=1977 | |||
|discontinued=(?) | |||
|designers= | |||
|manuals= | |||
* [[Media:061-1427-00.pdf|Tektronix 035-5031-00 Manual]] (OCR) | |||
}} | }} | ||
It is a passive unit similar to one half of a [[7M11]] (and shares the same trigger pick-off/attenuator/compensator PCB, part [[670-1147-00]]), but in a TM500 plugin form factor so it be inserted into a TM500, TM5000 or [[5000-series scopes|5000-series oscilloscope]] mainframe, or operated standalone outside an enclosure. | |||
It is a passive unit similar to one half of a [[7M11]] but in a TM500 plugin form factor so it be inserted into a TM500, TM5000 or [[5000-series scopes|5000-series oscilloscope]] mainframe. | |||
Delay line connections are 50 Ω [[GR-874 connector]]s, the trigger output is through a [[BNC connector]]. | Delay line connections are 50 Ω [[GR-874 connector]]s, the trigger output is through a [[BNC connector]]. | ||
Line 16: | Line 23: | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Photos== | |||
<gallery> | |||
Tek 035-5031-00 1.jpg | |||
Tek 035-5031-00 2.jpg | |||
Tek 035-5031-00 3.jpg | |||
</gallery> | |||
[[Category:Delay lines]] | [[Category:Delay lines]] | ||
[[Category:GR874]] | [[Category:GR874]] |
Latest revision as of 02:32, 18 February 2024
The Tektronix 035-5031-00 is a delay line plug-in for the TM500 system.
It is a passive unit similar to one half of a 7M11 (and shares the same trigger pick-off/attenuator/compensator PCB, part 670-1147-00), but in a TM500 plugin form factor so it be inserted into a TM500, TM5000 or 5000-series oscilloscope mainframe, or operated standalone outside an enclosure.
Delay line connections are 50 Ω GR-874 connectors, the trigger output is through a BNC connector.
Key Specifications
Impedance | 50 Ω |
---|---|
Delay | 75±1 ns |
Rise time | 175 ps |
Attenuation | ×2 (delayed output) |
Trigger output | attenuated ×5, 600 ps rise time |