TDS3012: Difference between revisions
No edit summary |
No edit summary |
||
(10 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar | | {{Oscilloscope Sidebar | ||
|manufacturer=Tektronix | |||
summary=Digital Storage 100 MHz 2-channel scope | | |series=TDS series scopes | ||
image=TDS3012_Waveform_image.jpg | | |model=TDS3012 | ||
caption=Tektronix TDS3012 | | |summary=Digital Storage 100 MHz 2-channel scope | ||
introduced=1998 | | |image=TDS3012_Waveform_image.jpg | ||
discontinued=? | | |caption=Tektronix TDS3012 | ||
manuals= | |introduced=1998 | ||
* [[Media: 071-0274-01.pdf| 071-0274-01 TDS3000 Series User Manual]] | |discontinued=(?) | ||
* [[Media: 071-0382-01.pdf| 071-0382-01 TDS3000 Series Service Manual]] | |designers= | ||
* [[Media: TDS3000C Series Datasheet.pdf| TDS3000C Series Datasheet]] | |manuals= | ||
* [[Media: 071-0274-01.pdf| 071-0274-01 TDS3000 Series User Manual]] | |||
* [[Media: 071-0382-01.pdf| 071-0382-01 TDS3000 Series Service Manual]] | |||
* [[Media: TDS3000C Series Datasheet.pdf| TDS3000C Series Datasheet]] | |||
}} | }} | ||
The '''Tektronix TDS3012''' is a dual-channel, 100 MHz, 1.25 GS/s digital phosphor oscilloscope with a TFT color screen. | |||
This series of scopes combines 3,600 wfms/s continuous waveform capture rate and real-time intensity grading. It can run without AC power for up to three hours when TDS3BATC rechargeable lithium ion battery pack is installed. | |||
Besides the channel inputs and the EXT TRIG input (two-channel models only), a Floppy Disk Drive and Centronics Parallel | Besides the channel inputs and the EXT TRIG input (two-channel models only), a [[Floppy]] Disk Drive and Centronics [[Parallel printer interface]] was available on the original and B version of this oscilloscope series until the C version which replaced the [[Floppy]] with a [[USB connector]] drive, and [[Parallel printer interface]] was removed altogether. Optional Communication Modules were available such as the [[TDS3GM]] (GPIB/RS-232), [[TDS3VM]] ([[VGA Connector]]/[[RS-232 interface]]), [[TDS3EM]] ([[Ethernet]]/[[RS-232 interface]]), [[TDS3GV]] ([[GPIB]], [[RS-232 interface]]/[[VGA Connector]]), and the [[TDS3SDI]] 601 Serial/Digital Video Module. | ||
Up to four Applications modules can be added into the small | Up to four Applications modules can be added into the small compartment in the upper right corner to transform the oscilloscope into a specialized instrument for limit testing, telecommunications mask testing, and video troubleshooting. The [[TDS3AAM]] Advanced Analysis Module, [[TDS3LIM]] Limit Testing Module, [[TDS3TMT]] Telecommunications Mask Testing Module, and the [[TDS3VID]] Extended Video Analysis Module were available for added functionality. The [[TDS3TRG]] (Advanced Trigger) and [[TDS3FFT]] (Fast Fourier Transform) application modules were available in the original model of this oscilloscope series but made standard on the B and higher versions. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
Line 28: | Line 30: | ||
{{Spec | Waveform Measurements| 25 Automatic, waveform add, subtract, divide, and multiply math functions, Fast Fourier Transform (FFT), Advanced Math (Integrate, Differentiate, Define extensive algebraic expressions, math functions, scalars, user adjustable variables) }} | {{Spec | Waveform Measurements| 25 Automatic, waveform add, subtract, divide, and multiply math functions, Fast Fourier Transform (FFT), Advanced Math (Integrate, Differentiate, Define extensive algebraic expressions, math functions, scalars, user adjustable variables) }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | |||
* [https://github.com/andrewpono/TDS3000-Series-Gotek-FlashFloppy Instructions on replacing the floppy drive with a USB emulator] | |||
{{Documents|Link=TDS3012}} | |||
{{PatentLinks|TDS3012}} | |||
==Pictures== | ==Pictures== | ||
Line 33: | Line 40: | ||
TDS3012_Waveform_image.jpg | TDS3012_Waveform_image.jpg | ||
TDS3012_2.JPG | TDS3012_2.JPG | ||
tds3012b.jpg | tds3012b.jpg|TDS3012B | ||
Tek-TDS-3012B-mainboard-front.jpg|TDS3012B Mainbaord Front Side | |||
Tek-TDS-3012B-Mainboard-back.jpg|TDS3012B Mainbaord Back Side | |||
Tek-TDS3012B-Front-Panel-back.jpg|TDS3012B Front Panel Assembly Back Side | |||
Tek-TDS3012B-Display-assy-back.jpg|TDS3012B Display Assembly with CCFL Inverter | |||
</gallery> | </gallery> | ||
[[Category:TDS3000 series scopes]] | [[Category:TDS3000 series scopes]] |
Latest revision as of 04:37, 23 September 2024
The Tektronix TDS3012 is a dual-channel, 100 MHz, 1.25 GS/s digital phosphor oscilloscope with a TFT color screen.
This series of scopes combines 3,600 wfms/s continuous waveform capture rate and real-time intensity grading. It can run without AC power for up to three hours when TDS3BATC rechargeable lithium ion battery pack is installed.
Besides the channel inputs and the EXT TRIG input (two-channel models only), a Floppy Disk Drive and Centronics Parallel printer interface was available on the original and B version of this oscilloscope series until the C version which replaced the Floppy with a USB connector drive, and Parallel printer interface was removed altogether. Optional Communication Modules were available such as the TDS3GM (GPIB/RS-232), TDS3VM (VGA Connector/RS-232 interface), TDS3EM (Ethernet/RS-232 interface), TDS3GV (GPIB, RS-232 interface/VGA Connector), and the TDS3SDI 601 Serial/Digital Video Module.
Up to four Applications modules can be added into the small compartment in the upper right corner to transform the oscilloscope into a specialized instrument for limit testing, telecommunications mask testing, and video troubleshooting. The TDS3AAM Advanced Analysis Module, TDS3LIM Limit Testing Module, TDS3TMT Telecommunications Mask Testing Module, and the TDS3VID Extended Video Analysis Module were available for added functionality. The TDS3TRG (Advanced Trigger) and TDS3FFT (Fast Fourier Transform) application modules were available in the original model of this oscilloscope series but made standard on the B and higher versions.
Key Specifications
Bandwidth and Channels | 100 MHz; Analog Bandwidth Limit is 20 MHz; 2 Channels |
---|---|
Vertical Sensitivity | 1 mV to 10 V/div (1 MΩ), 1 mV to 1 V/div (50 Ω) |
Time Base Range | 4 ns to 10 s/div |
Sample Rate | 1.25 GS/s on each channel |
Record Length | 10 K points |
Waveform Measurements | 25 Automatic, waveform add, subtract, divide, and multiply math functions, Fast Fourier Transform (FFT), Advanced Math (Integrate, Differentiate, Define extensive algebraic expressions, math functions, scalars, user adjustable variables) |
Links
Documents Referencing TDS3012
- (no results)
Patents that may apply to TDS3012
Pictures
-
-
-
TDS3012B
-
TDS3012B Mainbaord Front Side
-
TDS3012B Mainbaord Back Side
-
TDS3012B Front Panel Assembly Back Side
-
TDS3012B Display Assembly with CCFL Inverter