H2462: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
mNo edit summary |
||
(6 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
[[File:H2462_schematic.png | thumb | 500px | H2462 schematic diagram (click to enlarge) ''(From [[Media:070-9710-03.pdf|TDS520B Component Service]], p.233)'']] | |||
{{Hybrid IC | |||
|Manufacturer=Tektronix | |||
|Model=H2462 | |||
|Part_nos= | |||
|an=an | |||
|Description=oscilloscope channel input module | |||
|Used_in=TDS510B;TDS520B;TDS524B;TDS540B;TDS544B;TDS620B;TDS640B;TDS644B;TDS680B;TDS684B;TDS714;TDS724;TDS744;TDS754;TDS782;TDS784;TDS794 | |||
|Designers= | |||
}} (attenuator and amplifier) implemented on a ceramic substrate. | |||
The suffix letter (e.g. H2462G) indicates the module revision. For repair purposes, the versions appear to be interchangeable. | |||
It has three differential outputs. The amplifier dies are [[M753]] and [[M777]]. | |||
All | ==Used in== | ||
* All [[TDS500]] series scopes since version B (e.g. [[TDS520B]]) | |||
* [[ | * All [[TDS600]] series scopes since version B (except [[TDS694]]) | ||
* All [[TDS700]] series scopes | |||
==Pictures== | ==Pictures== |
Latest revision as of 09:30, 13 December 2022
The Tektronix H2462 is an oscilloscope channel input module hybrid integrated circuit (attenuator and amplifier) implemented on a ceramic substrate.
The suffix letter (e.g. H2462G) indicates the module revision. For repair purposes, the versions appear to be interchangeable.
It has three differential outputs. The amplifier dies are M753 and M777.
Used in
- All TDS500 series scopes since version B (e.g. TDS520B)
- All TDS600 series scopes since version B (except TDS694)
- All TDS700 series scopes
Pictures
-
H2462G
-
H2462H
-
H2462J