Nelson-Ross PSA-011: Difference between revisions
No edit summary |
No edit summary |
||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{Plugin Sidebar| | {{Plugin Sidebar | ||
manufacturer=Nelson-Ross |type=PSA-011| | |manufacturer=Nelson-Ross | ||
summary=20 kHz Spectrum | |series=500-series scopes | ||
image=Nelson-ross-psa011-2.jpg | | |type=PSA-011 | ||
caption=Nelson-Ross PSA-011 front view| | |summary=20 kHz Spectrum Analyzer plug-in | ||
introduced=(?) | | |image=Nelson-ross-psa011-2.jpg | ||
discontinued=(?) | |caption=Nelson-Ross PSA-011 front view | ||
|introduced=(?) | |||
manuals= | |discontinued=(?) | ||
* [[Media:Nelson-ross psa-001 002 003 011 012 013 plug-ins instruction sch.pdf|Manual for Nelson-Ross 001, 002, 003, 011, 012, and 013 | |manuals= | ||
* [[Media:Nelson-ross psa-001 002 003 011 012 013 plug-ins instruction sch.pdf|Manual for Nelson-Ross 001, 002, 003, 011, 012, and 013]] | |||
}} | }} | ||
The '''Nelson-Ross PSA-011''' is a spectrum analyzer plug-in for [[500-series scopes]]. | The '''Nelson-Ross PSA-011''' is a spectrum analyzer plug-in for [[500-series scopes]]. | ||
Line 14: | Line 15: | ||
linear or log scale. | linear or log scale. | ||
{{MissingSpecs}} | |||
The voltage-controlled local oscillator is tuned | ==Internals== | ||
using a variable-reactance tube, V6, a [[6201]]. | The input is high-impedance and is AC-coupled. The PSA-011 is a single-conversion architecture with a pair of [[6BH6]] tubes serving as a balanced mixer. | ||
After IF filtering and amplification, the signal is detected using a [[1N34A]] germanium diode. | |||
The detected voltage from the diode directly drives pin 3 (vertical -) of the scope plug-in interface connector. | |||
Pin 1 (vertical +) of the scope plug-in interface connector is fed a DC vertical position voltage by the PSA-011. | |||
The voltage-controlled local oscillator is tuned using a variable-reactance tube, V6, a [[6201]]. | |||
There were at least two major versions produced, without changing the model number. Compare the picture from the manual below with the other front panel photographs. | There were at least two major versions produced, without changing the model number. Compare the picture from the manual below with the other front panel photographs. | ||
There was also a tracking generator, called the Nelson Ross 101 SYNCHRO-SWEEP Generator. These are very rare. | There was also a tracking generator, called the Nelson Ross 101 SYNCHRO-SWEEP Generator. These are very rare. | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
NR-011-manual-image.png|Front panel, as shown in manual. | |||
PC280162.JPG|Front | |||
PC280163.JPG|Front 2 | |||
PC280172.JPG|Front right | |||
PC280171.JPG|Front left | |||
PC280170.JPG|Bottom | |||
PC280165.JPG|Bottom 2 | |||
PC280166.JPG|Left | |||
PC280173.JPG|Rear right | |||
PC280174.jpg|Rear | |||
PC280169.JPG|Rear 2 | |||
PC280164.JPG|Rear 3 | |||
Nelson-ross_011_schem_sm.png|Schematic | Nelson-ross_011_schem_sm.png|Schematic | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|Nelson-Ross PSA-011}} | |||
[[Category:500 series plugins]] | [[Category:500 series plugins]] | ||
[[Category:Spectrum analyzers]] | [[Category:Spectrum analyzers]] | ||
[[Category:Nelson-Ross products]] | [[Category:Nelson-Ross products]] | ||
Latest revision as of 07:01, 6 December 2023
The Nelson-Ross PSA-011 is a spectrum analyzer plug-in for 500-series scopes. The center frequency range is 10 Hz to 20 kHz. It can display amplitude in linear or log scale.
Key Specifications
- please add
Internals
The input is high-impedance and is AC-coupled. The PSA-011 is a single-conversion architecture with a pair of 6BH6 tubes serving as a balanced mixer. After IF filtering and amplification, the signal is detected using a 1N34A germanium diode. The detected voltage from the diode directly drives pin 3 (vertical -) of the scope plug-in interface connector. Pin 1 (vertical +) of the scope plug-in interface connector is fed a DC vertical position voltage by the PSA-011.
The voltage-controlled local oscillator is tuned using a variable-reactance tube, V6, a 6201.
There were at least two major versions produced, without changing the model number. Compare the picture from the manual below with the other front panel photographs.
There was also a tracking generator, called the Nelson Ross 101 SYNCHRO-SWEEP Generator. These are very rare.
Pictures
-
Front panel, as shown in manual.
-
Front
-
Front 2
-
Front right
-
Front left
-
Bottom
-
Bottom 2
-
Left
-
Rear right
-
Rear
-
Rear 2
-
Rear 3
-
Schematic
Components
Some Parts Used in the Nelson-Ross PSA-011
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
1N34A | Discrete component | germanium point-contact diode | Nelson-Ross PSA-011 | |
6201 | Vacuum Tube (Dual Triode) | dual high-gain triode | Nelson-Ross PSA-011 | |
6BH6 | 154-0026-00 • 154-0285-00 | Vacuum Tube (Pentode) | pentode | 130 • 162 • 310 • 310A • 512 • 517 • 517A • 524 • Nelson-Ross PSA-011 |