|series=580-series scopes
|series=580-series scopes
|type=84
|type=84
|summary=Calibration Fixture
|summary=calibration fixture
|image=Tek_84_Front.jpeg
|image=Tek 067-0523-00 front.jpg
|caption=Type 84
|caption=Type 84
|introduced=1962  
|introduced=1962  
|discontinued=(?)  
|discontinued=(?)  
|designers=
|designers=John Gates;
|manuals=
|manuals=
* [http://w140.com/tek_84.pdf Tektronix Type 84 Manual (PDF)]
* [[Media:070-0345-01.pdf|Tektronix 067-0523-00 Manual]] (OCR)
* [[Media:067-0523-00 schematic.pdf|Tektronix 067-0523-00 Schematic (PDF)]]
* [[Media:067-0523-00 schematic.pdf|Tektronix 067-0523-00 Schematic]]
* [[Media:070-0345-01.pdf|Tektronix 067-0523-00 Manual (PDF, OCR)]]
* [[Media:Tek 067-0523-00 fcp aug 1966.pdf|Tektronix 067-0523-00 Factory Calibration Procedure, August 1966]]
* [[Media:Tek 067-0523-00 fcp aug 1966.pdf|Tektronix 067-0523-00 Factory Calibration Procedure, August 1966]]
}}
}}
The '''Tektronix Type 84''' is a calibration fixture plug-in for [[580-series scopes]].
The '''Tektronix Type 84''' is a calibration fixture plug-in for [[580-series scopes]].


It was renamed the '''067-0523-00''' during production. The Type 84 provides a
It was renamed the '''067-0523-00''' during production (SN 974+).
calibrated amplitude signal for adjusting gain, a fast-rise voltage step
for adjusting the impulse response of the vertical amplifiers in the scope,
and load resistors to test the power supply of the scope.  The fast-rise
pulses are produced by a [[mercury switch]] and are specified to have a
repetition rate of 550 to 750 pulses per second, with a rise time that is
''"considerably less than the response time of the vertical amplifier in a 580-series oscilloscope." ''


==Specifications==
The Type 84 provides a calibrated amplitude signal for adjusting gain,
[[Category:Specifications needed]] ''please add''
a fast-rise voltage step – produced by a [[mercury switch]] – for adjusting the impulse response of the vertical amplifiers in the scope,
and load resistors to test the power supply of the scope. 
It also features an external input to connect a time-mark generator during calibration.
 
{{BeginSpecs}}
{{Spec | Display signal | Calibration signal, fast-rise pulses, or external }}
{{Spec | Calibration reference signal | 200 mV, front-panel check }}
{{Spec | Pulse amplitude | Adjustable to plus or minus 4 cm deflection }}
{{Spec | Pulse repetition rate | 550 to 750 pulses per second }}
{{Spec | Pulse rise time | "considerably less than the response time of the vertical amplifier in a 580-series oscilloscope." }}
{{EndSpecs}}


==Pictures==
==Pictures==
<gallery>
<gallery>
Tel_84_Front.jpeg | Front
Tek 067-0523-00 front.jpg  | 067-0523-00 Front
067-0523-00 cat.jpg
Tel_84_Front.jpeg         | Type 84 Front
Tek 067-0523-00.jpg
Tek 067-0523-00 1.jpg | 067-0523-00
Tek 067-0523-00 2.jpg | 067-0523-00
Tek 067-0523-00 3.jpg | 067-0523-00
Tek 067-0523-00 4.jpg | 067-0523-00
Tek 84 1.jpg
Tek 84 2.jpg
Tek 84 3.jpg
Tek 84 4.jpg
Tek 067-0523-00 internal1.jpg | 067-0523-00
Tek 067-0523-00 internal2.jpg | 067-0523-00
Tek 067-0523-00 rear.jpg      | 067-0523-00
Tek 067-0523-00 10.jpeg | 067-0523-00
Tek 067-0523-00 12.jpeg | 067-0523-00
Tek 067-0523-00 13.jpeg | 067-0523-00
Tek 067-0523-00 14.jpeg | 067-0523-00
Tek 067-0523-00 5.jpeg | 067-0523-00
Tek 067-0523-00 6.jpeg | 067-0523-00
Tek 067-0523-00 7.jpeg | 067-0523-00
</gallery>
 
'''Schematics'''
<gallery>
Type-84-schem.png
Type-84-schem.png
Tek 067-0523-00.jpg
Tek 067-0523-00 1.jpg|067-0523-00
Tek 067-0523-00 2.jpg|067-0523-00
Tek 067-0523-00 3.jpg|067-0523-00
Tek 067-0523-00 4.jpg|067-0523-00
Tek 84 1.jpg|84
Tek 84 2.jpg|84
Tek 84 3.jpg|84
Tek 84 4.jpg|84
Tek 067-0523-00 internal1.jpg|067-0523-00
Tek 067-0523-00 internal2.jpg|067-0523-00
Tek 067-0523-00 rear.jpg|067-0523-00
</gallery>
</gallery>



Latest revision as of 07:43, 8 December 2023

Tektronix 84
calibration fixture
Type 84

Compatible with 580-series scopes

Produced from 1962 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix Type 84 is a calibration fixture plug-in for 580-series scopes.

It was renamed the 067-0523-00 during production (SN 974+).

The Type 84 provides a calibrated amplitude signal for adjusting gain, a fast-rise voltage step – produced by a mercury switch – for adjusting the impulse response of the vertical amplifiers in the scope, and load resistors to test the power supply of the scope. It also features an external input to connect a time-mark generator during calibration.

Key Specifications

Display signal Calibration signal, fast-rise pulses, or external
Calibration reference signal 200 mV, front-panel check
Pulse amplitude Adjustable to plus or minus 4 cm deflection
Pulse repetition rate 550 to 750 pulses per second
Pulse rise time "considerably less than the response time of the vertical amplifier in a 580-series oscilloscope."