7D14: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
(part ref.)
Line 40: Line 40:
A differential FET buffer + bipolar amplifier stage drives a counter gate that uses a 10 mA [[tunnel diode]] as the switching element.  
A differential FET buffer + bipolar amplifier stage drives a counter gate that uses a 10 mA [[tunnel diode]] as the switching element.  


The first decade is implemented as a divide-by-2 ECL flip-flop followed by a 5-stage ring counter made with discrete transistor pairs (note circular layout) and some logic to BCD-encode the count result.
The first decade is implemented as a divide-by-2 ECL flip-flop ([[156-0377-00]]) followed by a 5-stage ring counter made with discrete transistor pairs (note circular layout) and some logic to BCD-encode the count result.


The following seven counter stages are conventional TTL decade ripple counters (N8292A).
The following seven counter stages are conventional TTL decade ripple counters (N8292A).

Revision as of 06:02, 3 October 2014

Template:Plugin Sidebar 2

The Tektronix 7D14 is a 525 MHz frequency counter plug-in for 7000 series mainframes.

It uses the mainframe's readout system to display an eight-digit count on the CRT. Modes include frequency, frequency ratio and events count using manual or external gate.

When installed in a horizontal compartment, it can count the trigger pickoff from a vertical amplifier unit. This allows simultaneous viewing and counting of a signal in four-bay mainframes.

In a vertical compartment, the trigger signal (i.e. the "shaped" input) can be displayed as the module's Y output.

Specifications

Key Specifications

Frequency 525 MHz (5 MHz bandwidth limiting switch available)
Sensitivity 100 mV to 10 V
Input Impedance 50 Ω or 1 MΩ // 20 pF on external input, 1.5 Div internal when set to "Trig Source"
Gate time 1 ms to 10 s
Display time 0.1 s to 5 s or infinite
Features
  • Gate monitor output / Ext Gate input (BSM)
  • 1 MHz reference monitor output / Ext Ref input (BSM)

Internals

An input section using relays selects the counter signal from the internal trigger path or external input, and activates 50 Ω termination and/or attenuators.

A differential FET buffer + bipolar amplifier stage drives a counter gate that uses a 10 mA tunnel diode as the switching element.

The first decade is implemented as a divide-by-2 ECL flip-flop (156-0377-00) followed by a 5-stage ring counter made with discrete transistor pairs (note circular layout) and some logic to BCD-encode the count result.

The following seven counter stages are conventional TTL decade ripple counters (N8292A).

The counter outputs are multiplexed onto a common 4-bit bus using open-collector NAND gates under control of the mainframe's readout system. The multiplexed digit value feeds a D/A converter (Tek 155-0038-01) that in turn drives the analog row and column returns to the readout system. A separate blanking logic eliminates leading zeroes and displays a ">" sign in the leftmost column if the counter overflows.

Links

Pictures