It is designed to operate as an accessory for the [[7L12]] and [[7L13]] Spectrum Analyzers, intended for measuring-signal-to noise, radiation, and field intensity on CATV, television, and FM installations. Other uses include radio-system servicing and measurements, as well as increasing sensitivity for EMI measurements.


==Specifications==
{{BeginSpecs}}
[[Category:Specifications needed]] ''please add''
{{Spec | Frequency Range | 30 to 890 MHz }}
{{Spec | Input Impedance | 75 Ω }}
{{Spec | VSWR | <2:1 }}
{{Spec | Reference Level | +79 dBmV to 0 dBmV in 1 dB steps }}
{{Spec | Intermodulation | >70 dB down}}
{{EndSpecs}}
 
==Links==
* [[Media:Tekscope 1976 V8 N2.pdf | Tekscope Vol. 8 No. 2 1976]]: New Products


==Pictures==
==Pictures==

Revision as of 22:43, 27 June 2017

Tektronix AM511
CATV pre-amplifier
Tektronix AM511

Produced from 1976 to 1980

Manuals
*Manual needed - please add
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix AM511 is a CATV pre-amplifier plug-in for the TM500 system.

It is designed to operate as an accessory for the 7L12 and 7L13 Spectrum Analyzers, intended for measuring-signal-to noise, radiation, and field intensity on CATV, television, and FM installations. Other uses include radio-system servicing and measurements, as well as increasing sensitivity for EMI measurements.

Key Specifications

Frequency Range 30 to 890 MHz
Input Impedance 75 Ω
VSWR <2:1
Reference Level +79 dBmV to 0 dBmV in 1 dB steps
Intermodulation >70 dB down