S-4: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(compatible list)
(sampler hybrid photos)
Line 28: Line 28:
The S-4 sampling gate is based upon a traveling wave trapped-charge transmission line in which the sampling window is set by the propagation time of a pulse edge through a thick-film transmission line. This technique requires only a sharp pulse edge rather than a precise pulse width, which is harder to generate.
The S-4 sampling gate is based upon a traveling wave trapped-charge transmission line in which the sampling window is set by the propagation time of a pulse edge through a thick-film transmission line. This technique requires only a sharp pulse edge rather than a precise pulse width, which is harder to generate.
The sampling diodes are housed in a special coaxial connector that provides a high bandwidth signal path.
The sampling diodes are housed in a special coaxial connector that provides a high bandwidth signal path.
To disassemble the sampler hybrid, first remove it from the sampler board as per the manual.  Remove the input
connector using a 7/32" wrench and remove the 20 dB attenuator with small plyers.  The ceramic board is held
to the housing using roll pins that can be pressed out with a 0.030" pin punch.  The hybrid has six diodes,
each about 0.75mm square.  The cathodes are glued to the gold substrate with conductive epoxy and the anodes
are wire-bonded (twice) over a gap to the next step in the strobe line.  It appears that a standard beam-lead
diode may fit across the gap but cleanly removing a failed diode without damaging the substrate would be
quite difficult.


==Links==
==Links==
Line 40: Line 48:
File:S4_right.jpg|Right view
File:S4_right.jpg|Right view
File:S4 schem.png|Schematic
File:S4 schem.png|Schematic
File:Tektronix-S4-sampler-board-strobe.jpg|Sampler board, strobe side
File:Tektronix-S4-sampler-board-preamp.jpg|Sampler board, preamp side
File:Tektronix-S4-sampler-board-hybrid.jpg|Sampler board, disassembled with parts orientation
File:Tektronix-S4-hybrid-internal.jpg|Microphotograph of sampler hybrid
</gallery>
</gallery>




[[Category:7000 and 3S series sampling heads]]
[[Category:7000 and 3S series sampling heads]]

Revision as of 18:15, 22 July 2015

Template:Plugin Sidebar 2 The Tektronix S-4 is a sampling head for 7000- and 3S-series samplers. It was designed by George Frye and introduced in 1968. It is the fastest of the S-series plug-in samplers. (An interesting comparison of different sampling heads is found in "AN-3042a, Revision 1, 2/89".)

Key Specifications

Rise time 25 ps (observed with S-50 or S-52, 35 ps)
Bandwidth 14.5 GHz
Input impedance 50 Ω (terminated SMA port)
Input range operating, 1 Vp-p; max. safe overload, ±5 V
Noise < 5 mV
Features
  • trigger signal pick-off for internal triggering

Internals

The S-4 sampling gate is based upon a traveling wave trapped-charge transmission line in which the sampling window is set by the propagation time of a pulse edge through a thick-film transmission line. This technique requires only a sharp pulse edge rather than a precise pulse width, which is harder to generate. The sampling diodes are housed in a special coaxial connector that provides a high bandwidth signal path.

To disassemble the sampler hybrid, first remove it from the sampler board as per the manual. Remove the input connector using a 7/32" wrench and remove the 20 dB attenuator with small plyers. The ceramic board is held to the housing using roll pins that can be pressed out with a 0.030" pin punch. The hybrid has six diodes, each about 0.75mm square. The cathodes are glued to the gold substrate with conductive epoxy and the anodes are wire-bonded (twice) over a gap to the next step in the strobe line. It appears that a standard beam-lead diode may fit across the gap but cleanly removing a failed diode without damaging the substrate would be quite difficult.

Links

Pictures