P6021: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 31: | Line 31: | ||
==Manuals== | ==Manuals== | ||
* [http://w140.com/tek_P6021.pdf Tektronix P6021 Manual (PDF)] | * [http://w140.com/tek_P6021.pdf Tektronix P6021 Manual (PDF), no schematics] | ||
* [http://w140.com/tek_p6021_1971_cat.pdf Description in 1971 Catalog (PDF)] | * [http://w140.com/tek_p6021_1971_cat.pdf Description in 1971 Catalog (PDF)] | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek-p6021.jpg | Tektronix P6021 with passive termination box | |||
Tek-p6021-catalog.jpg | P6021 catalog image | |||
</gallery> | </gallery> | ||
[[Category:Oscilloscope current probes]] | [[Category:Oscilloscope current probes]] | ||
[[Category:Introduced in 1969]] | [[Category:Introduced in 1969]] |
Revision as of 12:34, 6 October 2016
The Tektronix P6021 is an AC current probe for oscilloscopes. It can be used with the included passive termination, a type 134 current probe amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in. Bandwidth is up to 52 MHz.
The sister model P6022 has higher bandwidth but also a higher LF cut-off frequency and lower peak current rating.
Specifications
P6021 passive | P6021 + 134 | P6022 passive | P6022 + 134 | |
---|---|---|---|---|
Sensitivity | 2 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
1 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
Bandwidth (-3 dB) | 60 MHz @ 10 mA/mV | > 40 MHz | 200 MHz @ 10 mA/mV | > 70 MHz |
LF limit (-3 dB) | 450 Hz @ 2 mA/mV 120 Hz @ 10 mA/mV |
< 12 Hz | 8500 Hz @ 1 mA/mV 935 Hz @ 10 mA/mV |
< 100 Hz |
Maximum current | 15 Ap-p | 6 Ap-p (> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz) |
Manuals
Pictures
-
Tektronix P6021 with passive termination box
-
P6021 catalog image