P6021: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 39: | Line 39: | ||
Tek-p6021.jpg | Tektronix P6021 with passive termination box | Tek-p6021.jpg | Tektronix P6021 with passive termination box | ||
Tek-p6021-catalog.jpg | P6021 catalog image | Tek-p6021-catalog.jpg | P6021 catalog image | ||
P6021A.jpg | P6021A | |||
</gallery> | |||
'''Measurement examples''' | |||
<gallery> | |||
P6021-bat41-1.jpg | Measuring diode reverse recovery | P6021-bat41-1.jpg | Measuring diode reverse recovery | ||
P6021-bat41-2.jpg | BAT41 diode reverse recovery, 20 mA/Div | P6021-bat41-2.jpg | BAT41 diode reverse recovery, 20 mA/Div | ||
</gallery> | </gallery> | ||
Comparison of P6022 with passive termination @ 10 mA/Div (top trace) vs. P6021+134 (bottom trace). | Comparison of P6022 with passive termination @ 10 mA/Div (top trace) vs. P6021+134 (bottom trace).<br /> | ||
The a signal shown is a sawtooth from a HP3325A @ 5 V<sub>p-p</sub> into 50 Ω = 100 mA<sub>p-p</sub>. | |||
<gallery> | <gallery> | ||
P6021-6022-100hz.jpg | 100 Hz | P6021-6022-100hz.jpg | 100 Hz |
Revision as of 04:20, 22 April 2017
The Tektronix P6021 is a 125-turn AC current probe for oscilloscopes. It can be used with the included passive termination, a type 134 current probe amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in. Bandwidth is up to 52 MHz.
The sister model P6022 has higher bandwidth but also a higher LF cut-off frequency and lower peak current rating.
Specifications
P6021 passive | P6021 + 134 | P6022 passive | P6022 + 134 | |
---|---|---|---|---|
Sensitivity | 2 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
1 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
Bandwidth (-3 dB) | 60 MHz @ 10 mA/mV | > 40 MHz | 200 MHz @ 10 mA/mV | > 70 MHz |
LF limit (-3 dB) | 450 Hz @ 2 mA/mV 120 Hz @ 10 mA/mV |
< 12 Hz | 8500 Hz @ 1 mA/mV 935 Hz @ 10 mA/mV |
< 100 Hz |
Maximum current | 15 Ap-p | 6 Ap-p (> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz) |
Manuals
- Tektronix P6021 Manual (PDF), earlier version with termination schematics
- Tektronix P6021 Manual (PDF), no schematics
- Description in 1971 Catalog (PDF)
Pictures
-
Tektronix P6021 with passive termination box
-
P6021 catalog image
-
P6021A
Measurement examples
-
Measuring diode reverse recovery
-
BAT41 diode reverse recovery, 20 mA/Div
Comparison of P6022 with passive termination @ 10 mA/Div (top trace) vs. P6021+134 (bottom trace).
The a signal shown is a sawtooth from a HP3325A @ 5 Vp-p into 50 Ω = 100 mAp-p.
-
100 Hz
-
1 kHz
-
10 kHz