Line 1: | Line 1: | ||
The '''Tektronix P6009''' is a 120 MHz, 100× probe for scopes with 1 MΩ input impedance. Maximum input voltage is 1.5 kV (at DC). | The '''Tektronix P6009''' is a 120 MHz, 100× probe for scopes with 1 MΩ input impedance. Maximum input voltage is 1.5 kV (at DC). | ||
It has a contact for readout information (fixed 6.8 kΩ resistor) but no Identify switch. | It has a contact for [[7000 series readout system|readout information]] (fixed 6.8 kΩ resistor) but no Identify switch. | ||
==Manuals== | ==Manuals== |
Revision as of 12:34, 24 August 2017
The Tektronix P6009 is a 120 MHz, 100× probe for scopes with 1 MΩ input impedance. Maximum input voltage is 1.5 kV (at DC).
It has a contact for readout information (fixed 6.8 kΩ resistor) but no Identify switch.