P: Difference between revisions
No edit summary |
No edit summary |
||
Line 25: | Line 25: | ||
It does contain a [[selenium rectifiers|selenium rectifier]] and a [[mercury switch]]. | It does contain a [[selenium rectifiers|selenium rectifier]] and a [[mercury switch]]. | ||
The selenium rectifier in the Type P has four sections and full-wave rectifies | The selenium rectifier in the Type P has four sections and full-wave rectifies | ||
the 6. | the 6.3 V<sub>AC</sub> that is supplied by the scope mainframe on pins 13 and 14. | ||
The 120 Hz (assuming 60 Hz mains) component of the full-wave rectified waveform | The 120 Hz (assuming 60 Hz mains) component of the full-wave rectified waveform | ||
is applied to the coil of the mercury switch to drive the opening and closing | is applied to the coil of the mercury switch to drive the opening and closing | ||
Line 33: | Line 33: | ||
best operating point. | best operating point. | ||
The Type P was the only new plug-in for [[introduced in 1959|1959]], | The Type P was the only new plug-in for [[introduced in 1959|1959]], except for the upgrade | ||
from Type 53/54[[C]] to Type [[CA]]. It was dropped after 1963, replaced by the [[TU-7]]. | from Type 53/54[[C]] to Type [[CA]]. It was dropped after 1963, replaced by the [[TU-7]]. | ||
Line 39: | Line 39: | ||
<gallery> | <gallery> | ||
Tek_type_p.jpg|Type P | |||
Type_p_inside.jpg|Type P | |||
Type_p_schem.png|Type P Schematic | |||
Tek 53-54p front.jpg|Type 53/54P | Tek 53-54p front.jpg|Type 53/54P | ||
Tek 53-54p inside.jpg|Type 53/54P | Tek 53-54p inside.jpg|Type 53/54P |
Revision as of 22:10, 2 May 2017
Template:Plugin Sidebar 2 The Tektronix Type P plug-in is a calibration aid introduced in 1959 for 500-series scopes.
It applies a fast (4 nanosecond risetime) voltage step to the mainframe vertical amplifier, via plug-in connector pins 1 and 3. The Type P is designed to simulate a perfectly-adjusted Type K plug-in being driven by a Type 107 square-wave generator, and is used when adjusting the peaking coils and the delay line. The idea is to calibrate a mainframe using Type P, then use this mainframe and a 107 to calibrate other plug-ins.
The Type P does not contain any tubes, transistors, or tunnel diodes. It does contain a selenium rectifier and a mercury switch. The selenium rectifier in the Type P has four sections and full-wave rectifies the 6.3 VAC that is supplied by the scope mainframe on pins 13 and 14. The 120 Hz (assuming 60 Hz mains) component of the full-wave rectified waveform is applied to the coil of the mercury switch to drive the opening and closing of the contacts. An adjustable fraction of the DC component of the full-wave rectified waveform is applied to the coil of the mercury switch to create a constant component in the magnetic field to bias the switch contacts to the best operating point.
The Type P was the only new plug-in for 1959, except for the upgrade from Type 53/54C to Type CA. It was dropped after 1963, replaced by the TU-7.
Pictures
-
Type P
-
Type P
-
Type P Schematic
-
Type 53/54P
-
Type 53/54P