2К11: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar
title=2К11 |
|manufacturer=Vilnius Research
summary=Calibration plugin |
|series=Soviet 7000-series clones
image=2К11_front.jpg |  
|type=2К11  
caption=2К11 front panel |
|summary=Calibration plugin  
series=[[Soviet 7000-series clones]]|
|image=2К11_front.jpg  
introduced=(?) |
|caption=2К11 front panel  
discontinued=(?) |
|introduced=(?)  
manuals=
|discontinued=(?)  
|designers=
|manuals=
* [https://martinjonestechnology.files.wordpress.com/2017/02/2k11-technische-beschreibung-und-betriebsanleitung.pdf 2К11 Technical description and instruction manual (in German)]
* [https://martinjonestechnology.files.wordpress.com/2017/02/2k11-technische-beschreibung-und-betriebsanleitung.pdf 2К11 Technical description and instruction manual (in German)]
}}
}}
The '''2К11''' is a calibration plugin for [[Soviet 7000-series clones]]. It has the following operating modes:
The '''2К11''' is a calibration plugin for [[Soviet 7000-series clones]]. It has the following operating modes:
* step response
* step response

Revision as of 08:41, 15 August 2021

Vilnius Research 2К11
Calibration plugin
2К11 front panel

Compatible with Soviet 7000-series clones

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The 2К11 is a calibration plugin for Soviet 7000-series clones. It has the following operating modes:

  • step response
  • gain
  • power supply load test
  • readout test

The 'Y' button enables the step response mode. This generates an approx. 700 kHz rectangular wave with a fast (<1 ns) edge, either falling or rising as selected by the +/- button. This enables the rise time of the mainframe to be tested. The variable amplitude control can be used to align the waveform with the graticule's rise time markers.

The 'Eich.' button enables the gain test. The output of the plugin is then a 500 Hz squarewave which should be exactly 6 divisions high with the variable control in the 'cal' (fully anticlockwise) position.

The 'Belast.' button enables internal load resistors on the power supply rails.

The 'Zeichen' button runs the readout test which cycles through all 64 available readout characters at approximately 1-second intervals.

Sockets are provided on the front panel for measuring the positive and negative 5 V, 15 V and 48 V supplies.

The fast rise pulse generator uses 1И305А and 1И308В tunnel diodes.