The ''"Tektronix Type 1A5''' is a differential amplifier plug-in for [[500-series scopes]]. | |||
Bandwidth is 50 MHz down to 5 mV/div. The maximum differential sensitivity is 1 mV/div, with a bandwidth of 40 MHz. Common-mode rejection is 20,000 to 1 at low frequencies, deteriorating to 200:1 at 20 MHz. | |||
Like most Tektronix differential plug-ins, it has three modes: V<sub>A</sub>-V<sub>C</sub>, V<sub>A</sub>-V<sub>B</sub>, and V<sub>C</sub>-V<sub>B</sub>. V<sub>C</sub> is controlled by a ten-turn potentiometer and can vary from -5 V to +5 V (0.5 V on the 5 V/div to 20 V/div ranges). | |||
There is a front-panel jack for direct connection of the Type [[P6046|P6046 Active Differential Probe]]. | |||
Type 1A5 was [[introduced in 1967]], replacing Types [[W]] and [[Z]], and lasted until the end of the classic plug-in scope line in 1974. | |||
==Specifications== | |||
[[Category:Specifications needed]]''please add'' | |||
==Pictures== | |||
<gallery> | <gallery> | ||
Line 9: | Line 31: | ||
Image:1a5 left.jpg | Image:1a5 left.jpg | ||
</gallery> | </gallery> | ||
[[Category:500 series plugins]] |
Revision as of 06:04, 20 August 2014
Template:Plugin Sidebar 2 The "Tektronix Type 1A5' is a differential amplifier plug-in for 500-series scopes.
Bandwidth is 50 MHz down to 5 mV/div. The maximum differential sensitivity is 1 mV/div, with a bandwidth of 40 MHz. Common-mode rejection is 20,000 to 1 at low frequencies, deteriorating to 200:1 at 20 MHz.
Like most Tektronix differential plug-ins, it has three modes: VA-VC, VA-VB, and VC-VB. VC is controlled by a ten-turn potentiometer and can vary from -5 V to +5 V (0.5 V on the 5 V/div to 20 V/div ranges).
There is a front-panel jack for direct connection of the Type P6046 Active Differential Probe.
Type 1A5 was introduced in 1967, replacing Types W and Z, and lasted until the end of the classic plug-in scope line in 1974.
Specifications
please add