Spectrum Analyzer 9 kHz to 1.8 GHz
Tektronix 2714

Produced from 1993 to 2000

Manuals
Manuals – Specifications – Links – Pictures


The Tektronix 2714 is a CATV spectrum analyzer with a frequency range of 9 kHz to 1.8 GHz. The minimum resolution bandwidth is 300 Hz, and provides measurement resolution proportional to the frequency accuracy or span. With non-volatile memory (NVRAM) at 124 kB can save up to 108 displays of waveforms and markers, and up to 36 front panel setups, large user-defined key programs, and antenna factor tables.

The single and delta markers provide direct readout of frequency and amplitude information of any point along any displayed trace. Or, get the relative (delta) frequency and amplitude information between any two points along any displayed trace or between traces.

The 2714 Cable TV Spectrum Analyzer has features to support the measurements necessary to maintain a functional CATV system like: Automatic positioning of visual aural carriers, Visual and aural carrier levels and frequencies for selected channels, Survey of system visual and aural carrier levels and frequencies, Depth of modulation, Aural carrier deviation measurement, Visual carrier-to-noise measurement, and Visual to carrier amplitude and frequency difference measurements.

Additional features include Digital Storage Display (selectable acquisition modes of positive peak only, positive/negative peak, Max hold, Waterfall, and an analog sweep when digital storage is off), Ensemble Averaging, Internal Preamp, Internal Calibrator (accessed through Input Menu), Alternate Reference Level Units (dBm, dBmV, dBV, dBµV, dBµW, and dBµV/m), User-Definable Power-on Status, Center Measure, Graticule Illumination (for CRT photography), and Direct Plot/Print (Printers via Opt. 03 GPIB, or RS-232-C interface via Opt. 08).

Front panel inputs/outputs are: RF INPUT BNC connector (75Ω, +20 dBm Max, 100 V DC blocking capacitor); and OPTION Unknown connector (Service manual only indicates that the front panel position is for a Future Option. No internal tracking generators were available like with the other 2710, 2711, and 2712).

Rear panel inputs/outputs are: J101 SMA connector (Female SMA installed for Opt. 15), J102 EXT TRIG BNC connector (10 kΩ, 50V (DC + peak AC)), J103 DB9 connector Female (Not RS-232 compatible. Accessory connector: Pin 1 Video Input, Pin 2 Ground, Pin 3 Video Output, Pin 6 Sweep Gate, Pin 7 Sweep Output, all others unused), J104 Opt. 03: GPIB connector (IEEE Std 488 connector) or Opt. 08: RS-232 interface (Digital Communication Port.).

Key Specifications

Frequency Range 9 kHz to 1.8 GHz; Preamp limited to 600 MHz
Frequency Span Range (plus 0 Hz and MAX: 180 MHz/div) 1 kHz/div to 100 MHz/div in 1, 2, 5 sequence
Resolution Bandwidth Range -6 dB bandwidth selections are 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz, 300 kHz, 1 MHz and 5 MHz
RF Input impedance 75Ω
Maximum Safe Input Power +70 dBmV (0.1 W or 2.2 V) continuous peak, ≤100 V DC blocking capacitor
RF Attenuator Range 0 dB to 50 dB, 2 dB steps
Sensitivity (at 300 Hz RBW) -78 dBmV (-127 dBm); -90 dBmV (-139 dBm) with preamp on
Reference Level Range -70 dBm to +20 dBm; -23 dBmV to +66.9 dBmV
Sweep Speed Range 2 sec/Div to 1 µs/Div in 1, 2, 5 sequence
Triggering Modes Free Run, Internal, External, Line, TV Line, and TV Field
Displayed Average Noise −66 dBm to −100 dBm
Display Dynamic Range 80 dB
Dynamic Range ≥100 dBm
Internal Calibrator 100 MHz marker at +18.8 dBmV (-30 dBm)
Included Accessories PC Software; Power Cord; User Manual; Programmer Manual; Software Reference Manual; Front Cover; 75Ω BNC Connector, 75Ω F Connector; Choice of GPIB or RS-232 (Opt. 03 or Opt. 08)
Weight Standard accessories: 11.34 kg (25 lbs); Basic configuration: 10.21 kg (22.5 lbs)
Power 90 − 132 VAC, 48 to 440 Hz; 90 – 250 VAC, 48 to 63 Hz. At 115 VAC, 60 Hz, 90 W (standard), 105 W max (with options)
Operating Atmospherics Temperatures: 0 °C to +50 °C; Humidity: MIL-T-28800E; Altitude: Up to 4.6 km (15,000 ft)

Options

  • Opt. 03: GPIB Interface (cannot be combined with Opt. 08)
  • Opt. 05: 100 kHz to 1.8 GHz External Tracking Generator (includes option 15)
  • Opt. 07: Add 2704 Inverter/2705 Battery Pack
  • Opt. 08: RS-232 Port (cannot be combined with Opt. 03)
  • Opt. 15: Tek 1405 TV Sideband Adapter interface installed at J101 as SMA female
  • Opt. 30: Rackmount
  • Opt. 33: Travel Line Package (includes Rain cover, Accessory pouch, Gray filter and Carrying strap)