P6021: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
Line 57: Line 57:
|width=4em align=right|  $430
|width=4em align=right|  $430
|-
|-
! 2017 value
! 2021 value
|align=right|  $760
|align=right|  $850
|align=right|  $500
|align=right|  $550
|align=right| $960
|align=right| $1,070
|-
|-
|}
|}
Line 74: Line 74:
<gallery>
<gallery>
P6021-bat41-1.jpg | Measuring diode reverse recovery
P6021-bat41-1.jpg | Measuring diode reverse recovery
P6021-bat41-2.jpg | BAT41 diode reverse recovery, 20 mA/Div
P6021-bat41-2.jpg | Small-signal diode reverse recovery, 20 mA/Div
</gallery>
</gallery>
Comparison of P6022 with passive termination @ 10 mA/Div (top trace) vs. P6021+134 (bottom trace).<br />
Comparison of P6022 with passive termination @ 10 mA/Div (top trace) vs. P6021+134 (bottom trace).<br />
The signal shown is a sawtooth from a HP3325A @ 5 V<sub>p-p</sub> into 50 Ω = 100 mA<sub>p-p</sub>.  
The signal shown is a sawtooth from a HP3325A @ 5 V<sub>p-p</sub> into 50 Ω = 100 mA<sub>p-p</sub>.  
<gallery>
<gallery>
P6021-6022-100hz.jpg | 100 Hz
P6021-6022-100hz.jpg   | 100 Hz
P6021-6022-1000hz.jpg | 1 kHz
P6021-6022-1000hz.jpg | 1 kHz
P6021-6022-10000hz.jpg | 10 kHz
P6021-6022-10000hz.jpg | 10 kHz
</gallery>
</gallery>

Revision as of 05:22, 19 July 2021

P6021 with passive termination box

The Tektronix P6021 is a 125-turn AC current probe for oscilloscopes. It can be used with the included passive termination box (011-0105-00), a type 134 current probe amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in.

Bandwidth is up to 52 MHz.

The P6021 has a contact to short the ring around the 7A14's BNC input to ground, to switch frequency compensation and gain.

The sister model P6022 has higher bandwidth but also a higher LF cut-off frequency and lower peak current rating.

Specifications

P6021 passive P6021 + 134 P6021 + 7A14 P6022 passive P6022 + 134 P6022 + 7A14
Sensitivity 2 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
1 mA/Div to 1 A/Div 1 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
1 mA/Div to 1 A/Div
Bandwidth (-3 dB) 60 MHz @ 10 mA/mV > 40 MHz 50 MHz 200 MHz @ 10 mA/mV > 70 MHz 105 MHz
LF limit (-3 dB) 450 Hz @ 2 mA/mV
120 Hz @ 10 mA/mV
< 12 Hz 25 Hz 8500 Hz @ 1 mA/mV
935 Hz @ 10 mA/mV
< 100 Hz 250 Hz
Maximum current 15 Ap-p 6 Ap-p
(> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz)

Manuals

Prices

Year 1970 1974 1986
Catalog price $121 $100 $430
2021 value $850 $550 $1,070

Pictures

Measurement examples

Comparison of P6022 with passive termination @ 10 mA/Div (top trace) vs. P6021+134 (bottom trace).
The signal shown is a sawtooth from a HP3325A @ 5 Vp-p into 50 Ω = 100 mAp-p.