It provides X/Y/Z outputs for an external oscilloscope or X/Y monitor. It has a cable-attached passive 16-channel probe, the [[P6450]]. Alternatively, channels 0-3 can be switched to four [[BNC connector]] inputs with 1 MΩ impedance intended for external ×10 probes.
It has a cable-attached, passive 16-channel probe, the [[P6450]], and outputs analog X/Y/Z signals for an external oscilloscope or X/Y monitor. Alternatively, channels 0-3 can be switched to four [[BNC connector]] inputs with 1 MΩ impedance intended for external ×10 probes.  


The '''LA501W''' was a bundle of the LA501 with a [[WR501]] connected internally and providing word recognition trigger as well as data acquisition. In this case, there is no [[P6450]] probe, instead one or two [[P6451]] probes can be attached to the WR501.
The '''LA501W''' was a bundle of the LA501 with a [[WR501]] connected internally to provide word recognition trigger as well as data acquisition. In this case, there is no [[P6450]] probe; instead, one or two [[P6451]] probes are attached to the WR501.


The LA501 provides only a timing diagram with clock tick marks on the traces, and analog zoom/pan controls for focusing on a particular trace or detail.
The LA501 provides only a timing diagram with clock tick marks on the traces, and analog zoom/pan controls for focusing on a particular trace or detail.

Revision as of 01:39, 5 September 2020

Tektronix LA501
logic analyzer
Tektronix LA501

Produced from 1976 to 1978

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix LA501 is a logic analyzer plug-in for the TM500 system.

It has a cable-attached, passive 16-channel probe, the P6450, and outputs analog X/Y/Z signals for an external oscilloscope or X/Y monitor. Alternatively, channels 0-3 can be switched to four BNC connector inputs with 1 MΩ impedance intended for external ×10 probes.

The LA501W was a bundle of the LA501 with a WR501 connected internally to provide word recognition trigger as well as data acquisition. In this case, there is no P6450 probe; instead, one or two P6451 probes are attached to the WR501.

The LA501 provides only a timing diagram with clock tick marks on the traces, and analog zoom/pan controls for focusing on a particular trace or detail. Each channel can be positioned anywhere vertically to allow for timing comparisons.

Key Specifications

Memory 4096 bit (4ch/1024 bit, 8ch/512bit or 16ch/256bit)
Sampling rate up to 50 MHz (100 MHz @ 4ch)