107: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 11: Line 11:
|designers=
|designers=
|manuals=
|manuals=
* [https://w140.com/tek_107_clean.pdf Tektronix 107 Manual (PDF)]
* [[Media:IM-107-1.pdf|Tektronix 107 Manual]] (PDF)
* [https://w140.com/tek_fcp/tek_type_107_field_cal_proc.pdf Tektronix 107 Factory Calibration Procedure (PDF)]
* [https://w140.com/tek_fcp/tek_type_107_field_cal_proc.pdf Tektronix 107 Factory Calibration Procedure (PDF)]
}}
}}

Revision as of 10:45, 20 August 2021

Tektronix 107
square-wave generator
Tek 107 front

Produced from 1958 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 107 is a squarewave generator introduced in 1958.

It is designed to provide a clean waveform with fast edges and flat tops for the calibration of oscilloscopes.

Key Specifications

Output rectangular waveform, 100−500 mVp-p (variable) into 50 Ω
Rise time less than 3 ns (fixed) when terminated into 50 Ω
Repetition rate 400 kHz to 1 MHz (variable, uncalibrated)
Weight 5.9 kg (13 pounds)
Power 100 W

Internals

The signal path starts with an astable multivibrator composed of both halves of a 6BQ7A dual triode tube. The multivibrator circuit is cathode coupled to a pulse shaping circuit, and then to an output stage made from a single 6AU6 tube with a 50 Ω plate load, providing a controlled 50 Ω output impedance. The 50 Ω plate load keeps the voltage gain of output stage low, and the bandwidth high.