Note the [http://www.eevblog.com/forum/repair/tektronix-tg501-out-put-problem/ output must be terminated into 50 Ω] or there may be no signal at all. | Note the [http://www.eevblog.com/forum/repair/tektronix-tg501-out-put-problem/ output must be terminated into 50 Ω] or there may be no signal at all. | ||
{{BeginSpecs}} | |||
{{Spec | Interval | 1 ns to 5 s in 1−2−5 sequence }} | |||
{{Spec | Timing accuracy | Stability 1×10<sup>-5</sup>, long-term drift 1×10<sup>-5</sup> per month (with Option 1, 5×10<sup>-7</sup> / 1×10<sup>-7</sup> per month) }} | |||
{{Spec | Error Readout | Accuracy 1 digit (±0.1% points), Range to ±7.5% }} | |||
{{Spec | Amplitude | ≥1 V peak on 5 s through 10 ns; ≥750 mV<sub>p-p</sub> on 5 ns and 2 ns; ≥200 mV<sub>p-p</sub> on 1 ns (separate output) (all into 50 Ω) }} | |||
{{Spec | Trigger Output | Slaved to marker output from 5 s through 100 ns. Remains at 100 ns for all faster markers }} | |||
{{Spec | External Reference Input | 1 MHz, 5 MHz or 10 MHz; TTL compatible (internally hard wired so output frequencies counted down to 1 MHz) }} | |||
{{EndSpecs}} | |||