P6032: Difference between revisions
No edit summary |
No edit summary |
||
Line 6: | Line 6: | ||
|image=Tek p6032 kit 1.jpg | |image=Tek p6032 kit 1.jpg | ||
|caption=P6032 | |caption=P6032 | ||
|introduced= | |introduced=1962 | ||
|discontinued=(?) | |discontinued=(?) | ||
|designers=Murlan Kaufman | |designers=Murlan Kaufman |
Revision as of 01:36, 31 October 2021
The Tektronix P6032 is an 850 MHz cathode-follower probe, intended for use with samplers such as the 1S1, 3S1, 3S76, 4S1, and 4S2. It was designed by Murlan Kaufman.
There is an EC1000 subminiature triode in the probe body, which is why it gets slightly warm during operation.
Like all active probes, the P6032 requires power, and for this reason it has two connectors at the scope end of the cable. There is a four-pin power connector and a 50 Ω GR-874 connector for the signal.
The triode has limited dynamic range, so attenuator attachments are provided that attach to the tip of the probe. These attenuators also reduce the loading of the probe on the probed circuit.
What, exactly, does the clipping line in the probe body do? It appears to be 21 mm of RG-174 cable connected to the triode's cathode at one end, and open at the other end. The circuit description in the manual describes it vaguely, saying only that, "The clipping line reduces signal aberration to a minimum."
Key Specifications
Bandwidth | ≥850 MHz |
---|---|
Rise time | 0.4 ns max. |
Attenuation | 10× to 1000× in 1-2-5 steps with supplied attenuator heads, 3× without attenuator |
Dynamic range | ±0.15 V × attenuation |
Maximum input voltage | ±0.225 V × attenuation, de-rated for CW operation for 500× and 1000× attenuator heads |
Input resistance | 10 MΩ with any attenuator head, 3 MΩ without attenuator head |
Input capacitance | 3.6 pF (10× head) to 1.3 pF (1000× head), 7 pF without attenuator head |
Output impedance | not specified, calibrated for 50 Ω load |
DC offset | ≈0.5 V (not adjustable) |
Pictures
-
External view of P6032 without attenuator attachment
-
P6032 Schematic
-
Internal view of P6032 Probe tip connects directly to triode grid, which is a bare wire coming out of the top of the tube. Clipping line runs along the body of the probe to the left of the tube socket.
-
×20 attenuator tip
-
Internal view of power supply connector. Signal coax passes through undisturbed.
-
-
-
-
Some Parts Used in the P6032
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
EC1000 | Vacuum Tube (Triode) | subminiature triode | P6025 • P6032 |