The Tektronix 517 is a 50MHz scope [[introduced in 1950]] or [[introduced in 1951|1951]]. The power supply is an external box, like the [[507]], [[551]] and [[555]]. | The Tektronix 517 is a 50MHz scope [[introduced in 1950]] or [[introduced in 1951|1951]]. The power supply is an external box, like the [[507]], [[551]] and [[555]]. | ||
The 517 does not take plug-ins. There is also a 517A. | The 517 does not take plug-ins. There is also a 517A. | ||
== Historic Context == | |||
The 517 closely resembles a scope that Tektronix developed under a contract | The 517 closely resembles a scope that Tektronix developed under a contract | ||
for the US military during 1949 and 1950. (See link below.) | for the US military during 1949 and 1950. (See link below.) | ||
Line 9: | Line 11: | ||
</blockquote> | </blockquote> | ||
== External Power Supply == | |||
The external power supply and oscilloscope are connected by a removable cable | The external power supply and oscilloscope are connected by a removable cable | ||
with a Jones plug on one end and a Jones socket on the other end. | with a Jones plug on one end and a Jones socket on the other end. | ||
Line 33: | Line 36: | ||
-150V on pin 8. | -150V on pin 8. | ||
== Distributed Amplifiers == | |||
The 517 makes extensive use of the [[distributed amplifier]] concept. | The 517 makes extensive use of the [[distributed amplifier]] concept. | ||
Originally the [[5XP]] CRT was used, | Originally the [[5XP]] CRT was used, | ||
Line 67: | Line 71: | ||
* Gain Stage 4: single-ended, common-cathode, [[6AG7]] pentode | * Gain Stage 4: single-ended, common-cathode, [[6AG7]] pentode | ||
== High Voltage Power Supply == | |||
The 517 uses 24kV total acceleration voltage on the CRT. This is generated by the Type 420 High Voltage | The 517 uses 24kV total acceleration voltage on the CRT. This is generated by the Type 420 High Voltage | ||
Power Supply subsystem in the 517. It uses a 1.8kHz oscillator to produce the high voltage, unlike | Power Supply subsystem in the 517. It uses a 1.8kHz oscillator to produce the high voltage, unlike | ||
other Tek scopes which use HV oscillators in the ultrasonic range. | other Tek scopes which use HV oscillators in the ultrasonic range. | ||
The 517 has a switch on the front panel that selects between normal vertical sensitivity, | |||
which uses the full 24kV acceleration voltage, and "X2" mode, which drops the acceleration | |||
voltage to 12kV for a doubling of the vertical sensitivity. The control works by | |||
switching the the voltage division ratio of the feedback to the error amplifier in the HV supply. | |||
The power consumption of a 517 is 1250 watts. The indicator unit weighs 76 pounds and the external | The power consumption of a 517 is 1250 watts. The indicator unit weighs 76 pounds and the external | ||
power supply weighs 72 pounds. | power supply weighs 72 pounds. | ||
== CRTs Used in the 517 == | |||
517 units with serial numbers 101 through 925 use the DuMont 5XP CRT. | 517 units with serial numbers 101 through 925 use the DuMont 5XP CRT. | ||
Later units use a Tek-made CRT, the T517PxH/T54PxH, where "x" designates | Later units use a Tek-made CRT, the T517PxH/T54PxH, where "x" designates | ||
Line 79: | Line 89: | ||
6.6kV, 13.3kV, and 20kV. The Tek-made CRT has just one anode connection, 20kV, | 6.6kV, 13.3kV, and 20kV. The Tek-made CRT has just one anode connection, 20kV, | ||
and has 15 V/cm sensitivity at 24kV total acceleration voltage. | and has 15 V/cm sensitivity at 24kV total acceleration voltage. | ||
The 517 might be the only Tektronix instrument to have a part made of wood. | The 517 might be the only Tektronix instrument to have a part made of wood. | ||
Line 89: | Line 94: | ||
the probe power. | the probe power. | ||
== Comparison of 517 with 547 == | |||
In 1965, following the introduction of the 50MHz [[547]], the | In 1965, following the introduction of the 50MHz [[547]], the | ||
517 was discontinued. The 547 uses a non-distributed solid-state vertical | 517 was discontinued. The 547 uses a non-distributed solid-state vertical |
Revision as of 06:50, 7 May 2013
The Tektronix 517 is a 50MHz scope introduced in 1950 or 1951. The power supply is an external box, like the 507, 551 and 555. The 517 does not take plug-ins. There is also a 517A.
Historic Context
The 517 closely resembles a scope that Tektronix developed under a contract for the US military during 1949 and 1950. (See link below.)
Tektronix engineer Frank Hood recollects:
"A lot of progress was made in 1949 and 1950. Work was well underway by Logan Belleville, Dick Rhiger and Howard on the high speed scope, the 517. This used some brand new circuitry, distributed (or chain) amplifiers, using 16 to 20 tubes in each stage to get the power needed to handle the high frequencies. Our best prediction at that time was that there were only about 30 to 50 people in the whole world who had need of a scope with 60 to 100 megacycle bandwidth. As it turned out, when we brought out a higher speed scope, people were able to design equipment of greater bandwidth and needed even faster measuring instruments. The cycle was regenerative. Having faster, more accurate measuring tools created a demand for even more measuring tools. We eventually sold several thousand of this instrument."
External Power Supply
The external power supply and oscilloscope are connected by a removable cable with a Jones plug on one end and a Jones socket on the other end. Units with serial numbers from 101 through 1739 use 12-pin Jones 2412 connectors; after that it is a 16-pin Jones connector. (Was a 16-pin Jones connector used or did they go directory from the 12-pin Jones connector to the 16-pin Amphenol power connector used by the 555?) The voltages on the 12-pin connector are:
- Pin 1: +750V, regulated
- Pin 2: +475V, regulated
- Pin 3: +350V, unregulated
- Pin 4: +225V, regulated
- Pin 5: +150V, regulated
- Pin 6: Ground
- Pin 7: -250V, regulated
- Pin 8: +180V, unregulated
Later 517A units uses the same cable as the 551 and 555. Although they use the same cable, they are completely incompatible. The voltages are different. The 517's external power supply provides +750V to the indicator unit. The highest voltage provided by the 555 and 551 power supplies is +500V. Also, for example, the 517A has +180 on pin 8 of the 16-pin connector while the 555 and 551 have -150V on pin 8.
Distributed Amplifiers
The 517 makes extensive use of the distributed amplifier concept. Originally the 5XP CRT was used, which has 38V/cm vertical deflection sensitivity when operated with 24kV acceleration voltage. (Is this correct? It doesn't agree with the 5XP datasheet.) Since the vertical sensitivity at the input connector is 0.1V/cm, we can calculate that the voltage gain from the input connector to the vertical deflection plates is 380. For 4cm deflection, a 152-volt differential output swing is required. There are DC blocking capacitors at various places in the signal path. The slowest sweep is 20 us/cm. The 517 is not designed for low-frequency use. The vertical signal path is as follows:
- Optional B170-V external input attenuator
- Gain Stage 1: single-ended, six sections, distributed, 6AK5 pentodes
- Gain Stage 2: single-ended, six sections, distributed, 6AK5 pentodes
- Gain Stage 3: single-ended, seven sections, distributed, 6AK5 pentodes
- Trig Pickoff: one common-cathode 6CB6 pentode
- Signal Delay: 51 feet of RG63U 125-ohm coaxial cable
- Phase Splitter: single-ended in, differential out, three sections, distributed, 6CB6 pentode
- Gain Stage 4: differential, six sections, distributed, 6CB6 pentodes
- Gain Stage 5: differential, twelve sections, distributed, 6CB6 pentodes
There is a trigger amplifier in the 517 which can take its input from an external source, or from the trigger pickoff in the vertical pre-amp, or from the internal rate generator circuit. The trigger amplifier circuit has five stages:
- Phase Splitter: 6J6 dual-triode connected as a differential amplifier
- Gain Stage 1: single-ended, three sections, distributed, 6AK5 pentodes
- Gain Stage 2: single-ended, three sections, distributed, 6AK5 pentodes
- Gain Stage 3: single-ended, common-cathode, 6AG7 pentode
- Gain Stage 4: single-ended, common-cathode, 6AG7 pentode
High Voltage Power Supply
The 517 uses 24kV total acceleration voltage on the CRT. This is generated by the Type 420 High Voltage Power Supply subsystem in the 517. It uses a 1.8kHz oscillator to produce the high voltage, unlike other Tek scopes which use HV oscillators in the ultrasonic range. The 517 has a switch on the front panel that selects between normal vertical sensitivity, which uses the full 24kV acceleration voltage, and "X2" mode, which drops the acceleration voltage to 12kV for a doubling of the vertical sensitivity. The control works by switching the the voltage division ratio of the feedback to the error amplifier in the HV supply.
The power consumption of a 517 is 1250 watts. The indicator unit weighs 76 pounds and the external power supply weighs 72 pounds.
CRTs Used in the 517
517 units with serial numbers 101 through 925 use the DuMont 5XP CRT. Later units use a Tek-made CRT, the T517PxH/T54PxH, where "x" designates the phosphor type: 1, 2, 7, 11, or 16. The 5XP has three anode connections: 6.6kV, 13.3kV, and 20kV. The Tek-made CRT has just one anode connection, 20kV, and has 15 V/cm sensitivity at 24kV total acceleration voltage.
The 517 might be the only Tektronix instrument to have a part made of wood. There is a wood support for a large electrolytic capacitor, C826, which filters the probe power.
Comparison of 517 with 547
In 1965, following the introduction of the 50MHz 547, the 517 was discontinued. The 547 uses a non-distributed solid-state vertical amplifier, tunnel diode triggering, and a 6.5 V/cm CRT, thereby achieving good performance with lower cost, size, weight, complexity, and power consumption than the 517.
517A | 547 with 1A1 | |
---|---|---|
Bandwidth | 50MHz | 50MHz |
Sensitivity | 50 mV/cm | 50 mV/cm |
Cost in 1964 | $3500 | $2475 |
Size | scope + power supply | all in one |
Weight | 148 pounds | 71 pounds |
Complexity | 130 tubes | 45 tubes |
Power Consumption | 1250 watts | 510 watts |
Some 517 modification kits are listed on page 181 of the 1959 catalog.
Tek sold the 108 pulse generator as a tool for maintaining the 517, since a fast scope requires a fast pulse generator to test it.
- Final Report on Tektronix MILSPEC High Speed Scope (PDF, cleaned up and OCR)
- Final Report on Tektronix MILSPEC High Speed Scope (5MB, PDF, cleaned up)
- Final Report on Tektronix MILSPEC High Speed Scope (220MB, PDF, original)
- Tektronix 517 Calibration Guide
- Early 517 Manual (PDF)
- Early 517 Manual (PDF, OCR)
- Later Manual Covering the 517 and 517A (PDF)
- Later Manual Covering the 517 and 517A (PDF, OCR)
- Flynn and Johnson "Fast Grey Wedge Analyzer for High Input Rates"
- Thomas and Hearst, "An Electronic Scheme for Measurement of Exploding Wire Energy"
-
front
-
bottom internal
-
right internal
-
top internal
-
power supply internal
-
12-pin Jones socket on power supply
-
12-pin Jones plug
-
12-pin Jones plug inside
-
High voltage supply
-
Front view
-
12-pin Jones connector on indicator unit
-
Left internal view
-
Distributed vertical output amplifier
-
Wooden support for capacitor C826
-
Tek CRT Reference Chart
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
170 ohms Attenuator
-
-
Direct CRT access mod
-
Single-sweep mod