SW503: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 1: Line 1:
{{TM500 | mfg=Tektronix | type=SW503| function=sweep generator | class=signal generator | image=Tek sw503 front.jpg | introduced=1976 | discontinued=1978 |
{{TM500 | mfg=Tektronix | type=SW503| function=sweep generator | class=signal generator | image=Tek sw503 front.jpg | introduced=1976 | discontinued=1978 |
designers= |manuals=
designers= |manuals=
* [[Media:070-2051-00.pdf|SW503 Instruction Manual]] (OCR, PDF)
* [[Media:070-2051-00.pdf|SW503 Instruction Manual]] (OCR)
}}
}}
{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Frequency range | 1 to 400 MHz }}
{{Spec | Frequency range   | 1 to 400 MHz }}
{{Spec | Sweep width | 200 kHz to 400 MHz }}
{{Spec | Sweep width       | 200 kHz to 400 MHz }}
{{Spec | Sweep time | 10 ms to 100 s, decade steps plus vernier }}
{{Spec | Sweep time       | 10 ms to 100 s, decade steps plus vernier }}
{{Spec | Output | −40 to +10 dB<sub>m</sub> }}
{{Spec | Output           | −40 to +10 dB<sub>m</sub> into 50 Ω }}
{{Spec | Horizontal output | 0.5 V<sub>p-p</sub> }}
{{Spec | Horizontal output | 0.5 V<sub>p-p</sub> }}
{{Spec | Fixed markers | frequency comb with 1, 10, or 50 MHz base frequency }}
{{Spec | Fixed markers     | frequency comb with 1, 10, or 50 MHz base frequency }}
{{Spec | Variable marker | 1 to 400 MHz, digital readout on a [[DC502]] Opt.07 counter }}
{{Spec | Variable marker   | 1 to 400 MHz, digital readout on a [[DC502]] Opt.07 counter }}
{{Spec | Features |
* Amplitude control input (0 – 10 V)
* Frequency control input (0 – 10 V)
* Sweep trigger input (10 V pulse ≥1 μs)
}}
{{Spec|Options|
* Opt. 01 – 75 Ω output impedance
{{EndSpecs}}
{{EndSpecs}}
==Rear Interface==
{| class="wikitable"
|-
! Connector Pin
! Signal
|-
| 28B      || Y axis output (common on 28A)
|-
| 27B      || X axis output (common on 27A)
|-
| 24B      || Trigger input (common on 25B)
|-
| 21B      || Amplitude control input (0 – 10 V), common on 22B
|-
| 20B      || Frequency control input (0 – 10 V), common on 22B
|-
| 18B      || Start Count (0/+5 V; positive pulse to trigger the counter)
|-
| 18A      || Gate (0/+5 V; negative gate from counter)
|-
| 17B      || Counter Identify (grounded when counter is installed)
|-
| 16B      || Phase Lock Logic (+5 V: 100 kHz resolution; 0 V: 10 Hz resolution)
|-
| 15B      || CW Mode Logic (+5 V: dot marker function; 0 V: normal counter function)
|-
| 14B      || Sweep Generator Identify (grounded when SW503 is installed)
|-
|}


==Pictures==
==Pictures==

Revision as of 08:32, 10 July 2022

Tektronix SW503
sweep generator
Tektronix SW503

Produced from 1976 to 1978

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix SW503 is a sweep generator plug-in for the TM500 system.

Key Specifications

{{Spec|Options|
  • Opt. 01 – 75 Ω output impedance
Frequency range 1 to 400 MHz
Sweep width 200 kHz to 400 MHz
Sweep time 10 ms to 100 s, decade steps plus vernier
Output −40 to +10 dBm into 50 Ω
Horizontal output 0.5 Vp-p
Fixed markers frequency comb with 1, 10, or 50 MHz base frequency
Variable marker 1 to 400 MHz, digital readout on a DC502 Opt.07 counter
Features
  • Amplitude control input (0 – 10 V)
  • Frequency control input (0 – 10 V)
  • Sweep trigger input (10 V pulse ≥1 μs)


Rear Interface

Connector Pin Signal
28B Y axis output (common on 28A)
27B X axis output (common on 27A)
24B Trigger input (common on 25B)
21B Amplitude control input (0 – 10 V), common on 22B
20B Frequency control input (0 – 10 V), common on 22B
18B Start Count (0/+5 V; positive pulse to trigger the counter)
18A Gate (0/+5 V; negative gate from counter)
17B Counter Identify (grounded when counter is installed)
16B Phase Lock Logic (+5 V: 100 kHz resolution; 0 V: 10 Hz resolution)
15B CW Mode Logic (+5 V: dot marker function; 0 V: normal counter function)
14B Sweep Generator Identify (grounded when SW503 is installed)

Pictures