{{Spec | Scope Impedance Compensation Range P6135 | {{Spec | Scope Impedance Compensation Range | P6135: 1 MΩ // 13-17 pF; P6135A: 1 MΩ // 13-17 pF (red tip), 1 MΩ // 18-22 pF (black tip) and 1 MΩ // 45-49 pF (blue tip) }} | ||
{{Spec | Attenuation | Adjustable to ×10 }} | {{Spec | Attenuation | Adjustable to ×10 }} | ||
{{Spec | CMRR | 10,000:1 on [[11A33]], 20,000:1 on [[7A13]] }} | {{Spec | CMRR | 10,000:1 on [[11A33]], 20,000:1 on [[7A13]] }} |
Revision as of 14:26, 20 July 2022
The Tektronix P6135A is a differential probe pair matched to minimize differences in impedance and signal delay, to maintain CMRR up to 20,000:1 when used with differential amplifiers such as the 7A13, 7A22 or 11A33.
Key Specifications
Scope Impedance Compensation Range | P6135: 1 MΩ // 13-17 pF; P6135A: 1 MΩ // 13-17 pF (red tip), 1 MΩ // 18-22 pF (black tip) and 1 MΩ // 45-49 pF (blue tip) |
---|---|
Attenuation | Adjustable to ×10 |
CMRR | 10,000:1 on 11A33, 20,000:1 on 7A13 |
Max. input | ±500 V Maximum Common Mode Voltage |