Manuals – Specifications – Links – Pictures

The Tektronix P6109 is a 150 MHz, ×10, 3 m passive probe for scopes like the 2252 with 1 MΩ inputs. It has a BNC plug with a readout pin.

The P6109B is downrated to 100 MHz bandwidth but covers a larger compensation range.

Key Specifications

Attenuation 10x
Readout Pin Yes
     — P6109
Bandwidth 150 MHz
Maximum input 500 V DC + peak AC
Cable length 1.5 m, 2 m, and 3 m
Input impedance 10 MΩ // 11.8 pF (1.5 m), 15.5 pF (3.0 m)
Compensation range 1 MΩ // 18-22 pF
     — P6109B
Bandwidth 100 MHz
Maximum input 420 V DC + peak AC
Cable length 2 m
Input impedance 10 MΩ // 13.3 pF
Compensation range 1 MΩ // 15-35 pF