TG501A: Difference between revisions
(Removed redirect to TG501) Tag: Removed redirect |
(split TG501/TG501A pages) |
||
Line 1: | Line 1: | ||
{{TM500 | mfg=Tektronix | type=TG501A | function=time-mark generator | class=pulse generator | image=Tek | {{TM500 | mfg=Tektronix | type=TG501A | function=time-mark generator | class=pulse generator | image=Tek tg501a.jpg | introduced=1990 | discontinued=1995 | | ||
manuals= | manuals= | ||
* [[Media:070-7373-00.pdf|TG501A Manual 070-7373-00]] | * [[Media:070-7373-00.pdf|TG501A Manual 070-7373-00]] | ||
}} | }} | ||
It was replaced by the [[TG501A]] in 1990. | |||
Note the [https://www.eevblog.com/forum/repair/tektronix-tg501-out-put-problem/ output must be terminated into 50 Ω] or there may be no signal at all. | |||
{{BeginSpecs}} | |||
{{Spec | Interval | 1 ns to 5 s in 1−2−5 sequence }} | |||
{{Spec | Timing accuracy | Stability 1×10<sup>-5</sup>, long-term drift 1×10<sup>-5</sup> per month (with Option 1, 5×10<sup>-7</sup> / 1×10<sup>-7</sup> per month) }} | |||
{{Spec | Error Readout | Accuracy 1 digit (±0.1% points), Range to ±7.5% }} | |||
{{Spec | Amplitude | ≥1 V peak on 5 s through 10 ns; ≥750 mV<sub>p-p</sub> on 5 ns and 2 ns; ≥200 mV<sub>p-p</sub> on 1 ns (separate output) (all into 50 Ω) }} | |||
{{Spec | Trigger Output | Slaved to marker output from 5 s through 100 ns. Remains at 100 ns for all faster markers }} | |||
{{Spec | External Reference Input | 1 MHz, 5 MHz or 10 MHz; TTL compatible (internally hard wired so output frequencies counted down to 1 MHz) }} | |||
{{EndSpecs}} | |||
* Option 01 adds a 5 MHz tempature-compensated crystal oscillator (Y50), and a TTL decade counter (U50) for a stable, precise internal clock. | |||
''to be verified'' | |||
==Links== | |||
* [https://www.youtube.com/watch?v=U5LQpqwqNIU Tek TG501A Time Mark Gen Restoration] by NFM @ YouTube | |||
* [https://www.youtube.com/watch?v=yl29OOxyNf0 Tektronix TG501A Refresh and Check For a Viewer] by Zenwizard Studios @ YouTube | |||
{{Documents|Link=TG501A}} | |||
{{PatentLinks|TG501A}} | |||
==Rear Interface== | |||
<small> | |||
{| class="wikitable" | |||
|- | |||
! colspan="2" | Connector Pin | |||
! rowspan="2" | Description | |||
|- | |||
! Signal | |||
! Return | |||
|- | |||
| 28A || 27A || Marker Out (requires front BNC disconnection) | |||
|- | |||
| 27B || 28B || Trigger Out (requires front BNC disconnection) | |||
|- | |||
| 25A || 26A || Internal 1 MHz Clock Out (TTL) | |||
|- | |||
| 24B || 25B || External Clock Input | |||
|- | |||
| 26B || 22B || Data Good (High when BCD data valid) | |||
|- | |||
| 17A..20A || 22B || bit 4..1 BCD Display data, MSD | |||
|- | |||
| 21A..24A || 22B || bit 4..1 BCD Display data, LSD | |||
|- | |||
| 16A || 22B || Fast=Low, Slow=High | |||
|} | |||
</small> | |||
''to be verified'' | |||
==Internals== | |||
The TG501 internally produces a 1 MHz reference clock, either from an internal crystal oscillator, or from an externally supplied frequency. | |||
A 100 MHz VCO is phase-locked to this reference frequency (in fixed-frequency mode) or to the output of a variable 1 MHz astable multivibrator (in variable frequency mode). | |||
When the variable oscillator is in use, its frequency is digitally compared to the fixed 1 MHz reference and displayed as a deviation in percent with a pair of LEDs indicating the sign (fast or slow). | |||
A chain of dividers running off the 100 MHz clock provide the selectable output markers. | |||
The 1 ns output uses a [[step recovery diode]] (HP 5082-8872, part [[152-0503-00]]). | |||
''to be verified'' | |||
==Prices== | |||
tba | |||
==Pictures== | |||
<gallery> | |||
Tek tg501a.jpg | |||
</gallery> | |||
{{BetterPics}} | |||
==Parts== | |||
{{Parts|TG501A}} | |||
[[Category:Time mark generators]] | [[Category:Time mark generators]] |
Revision as of 02:48, 11 October 2024
The Tektronix TG501A is a time-mark generator plug-in for the TM500 system.
It was replaced by the TG501A in 1990.
Note the output must be terminated into 50 Ω or there may be no signal at all.
Key Specifications
Interval | 1 ns to 5 s in 1−2−5 sequence |
---|---|
Timing accuracy | Stability 1×10-5, long-term drift 1×10-5 per month (with Option 1, 5×10-7 / 1×10-7 per month) |
Error Readout | Accuracy 1 digit (±0.1% points), Range to ±7.5% |
Amplitude | ≥1 V peak on 5 s through 10 ns; ≥750 mVp-p on 5 ns and 2 ns; ≥200 mVp-p on 1 ns (separate output) (all into 50 Ω) |
Trigger Output | Slaved to marker output from 5 s through 100 ns. Remains at 100 ns for all faster markers |
External Reference Input | 1 MHz, 5 MHz or 10 MHz; TTL compatible (internally hard wired so output frequencies counted down to 1 MHz) |
- Option 01 adds a 5 MHz tempature-compensated crystal oscillator (Y50), and a TTL decade counter (U50) for a stable, precise internal clock.
to be verified
Links
- Tek TG501A Time Mark Gen Restoration by NFM @ YouTube
- Tektronix TG501A Refresh and Check For a Viewer by Zenwizard Studios @ YouTube
Documents Referencing TG501A
- (no results)
Rear Interface
Connector Pin | Description | |
---|---|---|
Signal | Return | |
28A | 27A | Marker Out (requires front BNC disconnection) |
27B | 28B | Trigger Out (requires front BNC disconnection) |
25A | 26A | Internal 1 MHz Clock Out (TTL) |
24B | 25B | External Clock Input |
26B | 22B | Data Good (High when BCD data valid) |
17A..20A | 22B | bit 4..1 BCD Display data, MSD |
21A..24A | 22B | bit 4..1 BCD Display data, LSD |
16A | 22B | Fast=Low, Slow=High |
to be verified
Internals
The TG501 internally produces a 1 MHz reference clock, either from an internal crystal oscillator, or from an externally supplied frequency.
A 100 MHz VCO is phase-locked to this reference frequency (in fixed-frequency mode) or to the output of a variable 1 MHz astable multivibrator (in variable frequency mode). When the variable oscillator is in use, its frequency is digitally compared to the fixed 1 MHz reference and displayed as a deviation in percent with a pair of LEDs indicating the sign (fast or slow).
A chain of dividers running off the 100 MHz clock provide the selectable output markers.
The 1 ns output uses a step recovery diode (HP 5082-8872, part 152-0503-00). to be verified
Prices
tba
Pictures
Better pictures needed - please contribute
Parts
Some Parts Used in the TG501A
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
152-0503-00 | 152-0503-00 | Discrete component | 500 ps step recovery diode | 1503C • TG501 • TG501A |