The risetime of a Type [[545]] oscilloscope with a Type CA plug-in is 15 nanoseconds,
The risetime of a Type [[545]] oscilloscope with a Type CA plug-in is 15 nanoseconds,
and the bandwidth is 24MHz.  Maximum vertical sensitivity is 50mV/div.
and the bandwidth is 24 MHz.  Maximum vertical sensitivity is 50 mV/div.


Type CA is an enhancement over its predecessor, Type [[C|53/54C]], adding
Type CA is an enhancement over its predecessor, Type [[C|53/54C]], adding
Line 10: Line 10:
also because the feature added was "ADDED".  It was [[introduced in 1959]] and
also because the feature added was "ADDED".  It was [[introduced in 1959]] and
discontinued in 1972 or 1973, making it not only the most-produced but
discontinued in 1972 or 1973, making it not only the most-produced but
also the longest-lived, if you include its Type C predecessors.
also the longest-lived, if you include its [[C|Type C predecessors]].


Late versions have [[Connectors#BNC|BNC]] connectors instead of  
Late versions have [[Connectors#BNC|BNC]] connectors instead of  
[[Connectors#UHF|UHF]] connectors.
[[Connectors#UHF|UHF]] connectors.


==Manuals==
* [http://bama.edebris.com/download/tek/ca/ca.djvu Tektronix Type CA Manual (DjVu)]
* [http://bama.edebris.com/download/tek/ca/ca.djvu Tektronix Type CA Manual (DjVu)]
* [http://w140.com/mmm/tek-ca.pdf Tektronix Type CA Manual (PDF)]
* [http://w140.com/mmm/tek-ca.pdf Tektronix Type CA Manual (PDF)]
* [http://w140.com/tek_fcp/tek_type_ca_factory_cal_proc.pdf Tektronix Type CA Factory Calibration Procedure (PDF)]
* [http://w140.com/tek_fcp/tek_type_ca_factory_cal_proc.pdf Tektronix Type CA Factory Calibration Procedure (PDF)]


==Pictures==
<gallery>
<gallery>
Image:type_ca_front.JPG|front view
Image:type_ca_front.JPG|front view

Revision as of 07:46, 29 June 2014

The Tektronix Type CA is the most common plug-in for 500-series scopes. Over 50,000 were produced.

The risetime of a Type 545 oscilloscope with a Type CA plug-in is 15 nanoseconds, and the bandwidth is 24 MHz. Maximum vertical sensitivity is 50 mV/div.

Type CA is an enhancement over its predecessor, Type 53/54C, adding ADDED mode to the A, B, CHOPPED, ALT repertoire. The "A" in "CA" stands not only for the fact that it is a modified, enhanced replacement, but also because the feature added was "ADDED". It was introduced in 1959 and discontinued in 1972 or 1973, making it not only the most-produced but also the longest-lived, if you include its Type C predecessors.

Late versions have BNC connectors instead of UHF connectors.

Manuals