title=067-0587-10 |
summary=Calibration Fixture |
image=Tek 067-0587-10.JPG |
caption=067-0587-10 |
series=[[7000-series scopes]] |
introduced=(?) |
discontinued=(?) |
manuals=
* [http://w140.com/tek_067-0587-10_op.pdf 067-0587-10 Operator's Manual]
* [http://w140.com/tek_067-0587-10_service.pdf 067-0587-10 Service Manual]
}}
The '''Tektronix 067-0587-10''' is a Calibration fixture / signal standardizer for [[7000-series scopes]].
The '''Tektronix 067-0587-10''' is a Calibration fixture / signal standardizer for [[7000-series scopes]].
It has the same performance specifications as the [[067-0587-02]] but is modified for
It has the same performance specifications as the [[067-0587-02]] but is modified for
compatibility with the [[7612D]].  In the [[067-0587-10]] the signal coming from the
compatibility with the [[7612D]].   
PRETRIG OUT generates one trigger for each staircase signal when used withthe TEST switch
 
in the GAIN position.  The [[067-0587-02]] generates a pretrigger signal on the PRETRIG OUT
In the [[067-0587-10]], the signal coming from the PRETRIG OUT generates one trigger for each  
connector while in any mode.
staircase signal when used with the TEST switch in the GAIN position.  The [[067-0587-02]]  
generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.


==Manuals==
{{MissingSpecs}}
* [http://w140.com/tek_067-0587-10_op.pdf 067-0587-10 Operator's Manual]
* [http://w140.com/tek_067-0587-10_service.pdf 067-0587-10 Service Manual]


==Pictures==
<gallery>
<gallery>
File:Tek 067-0587-10.JPG
File:Tek 067-0587-10.JPG
</gallery>
</gallery>
[[Category:Image needed]]
[[Category:Specifications needed]]


[[Category:7000 series special-function plugins]]
[[Category:7000 series special-function plugins]]
[[Category:Calibration fixtures]]
[[Category:Calibration fixtures]]

Revision as of 10:49, 17 October 2014

Template:Plugin Sidebar 2 The Tektronix 067-0587-10 is a Calibration fixture / signal standardizer for 7000-series scopes. It has the same performance specifications as the 067-0587-02 but is modified for compatibility with the 7612D.

In the 067-0587-10, the signal coming from the PRETRIG OUT generates one trigger for each staircase signal when used with the TEST switch in the GAIN position. The 067-0587-02 generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.

Key Specifications

  • please add

Pictures