P6022: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 1: Line 1:
The '''Tektronix P6022''' is an AC current probe for oscilloscopes.
[[File:P6022.jpg|right]]
The '''Tektronix P6022''' is an AC current probe for oscilloscopes. It can be used with the included passive termination, a [[134|type 134 current probe amplifier]], or a [[3A9]] or [[7A14]] current probe amplifier scope plug-in.  Bandwidth is at least 200 MHz with the passive termination. 


{{BeginSpecs}}
The sister model [[P6021]] has lower bandwidth but also a lower LF cut-off frequency and higher peak current rating.
{{Spec | Sensitivity | selectable, 1 mV/mA or 10 mV/mA }}
 
{{Spec | Bandwidth | (-3 dB with min. 300 MHz scope)
==Specifications==
* at 1 mV/mA: 8.5 kHz to 100 MHz
{| class="wikitable"
* at 10 mV/mA: 935 Hz to 120 MHz
!
}}
! P6021 passive
{{Spec | Maximum current |
! P6021 + [[134]]
* at 1 mV/mA: 6 A<sub>p-p</sub> sine between 10 kHz and 10 MHz
! P6022 passive
* at 10 mV/mA: 6 A<sub>p-p</sub> sine between 3 kHz and 10 MHz
! P6022 + [[134]]
}}
|-
{{EndSpecs}}
! Sensitivity
| 2 mA/mV or 10 mA/mV || 1 mA/Div to 1 A/Div<br/>(scope @ 50 mV/Div)
| 1 mA/mV or 10 mA/mV || 1 mA/Div to 1 A/Div<br/>(scope @ 50 mV/Div)
|-
! Bandwidth (-3 dB)
| 60 MHz @ 10 mA/mV    ||  > 40 MHz
| 200 MHz @ 10 mA/mV  ||  > 70 MHz
|-
! LF limit (-3 dB)
| 450 Hz @ 2 mA/mV<br/>120 Hz @ 10 mA/mV  ||  < 12 Hz
| 8500 Hz @ 1 mA/mV<br/>935 Hz @ 10 mA/mV  ||  < 100 Hz
|-
! Maximum current
| colspan="2" align="center" | 15 A<sub>p-p</sub>
| colspan="2" align="center" | 6 A<sub>p-p</sub><br>(> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz)
|}


==Manuals==
==Manuals==
Line 17: Line 33:
* [http://w140.com/tek_p6022.pdf Tektronix P6022 Manual (PDF)]
* [http://w140.com/tek_p6022.pdf Tektronix P6022 Manual (PDF)]


{{MissingPics}}


[[Category:Oscilloscope current probes]]
[[Category:Oscilloscope current probes]]
[[Category:Introduced in 1969]]
[[Category:Introduced in 1969]]

Revision as of 10:49, 15 June 2015

The Tektronix P6022 is an AC current probe for oscilloscopes. It can be used with the included passive termination, a type 134 current probe amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in. Bandwidth is at least 200 MHz with the passive termination.

The sister model P6021 has lower bandwidth but also a lower LF cut-off frequency and higher peak current rating.

Specifications

P6021 passive P6021 + 134 P6022 passive P6022 + 134
Sensitivity 2 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
1 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
Bandwidth (-3 dB) 60 MHz @ 10 mA/mV > 40 MHz 200 MHz @ 10 mA/mV > 70 MHz
LF limit (-3 dB) 450 Hz @ 2 mA/mV
120 Hz @ 10 mA/mV
< 12 Hz 8500 Hz @ 1 mA/mV
935 Hz @ 10 mA/mV
< 100 Hz
Maximum current 15 Ap-p 6 Ap-p
(> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz)

Manuals