P6022: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
The '''Tektronix P6022''' is an AC current probe for oscilloscopes. | [[File:P6022.jpg|right]] | ||
The '''Tektronix P6022''' is an AC current probe for oscilloscopes. It can be used with the included passive termination, a [[134|type 134 current probe amplifier]], or a [[3A9]] or [[7A14]] current probe amplifier scope plug-in. Bandwidth is at least 200 MHz with the passive termination. | |||
{ | The sister model [[P6021]] has lower bandwidth but also a lower LF cut-off frequency and higher peak current rating. | ||
==Specifications== | |||
{| class="wikitable" | |||
! | |||
! P6021 passive | |||
! P6021 + [[134]] | |||
! P6022 passive | |||
! P6022 + [[134]] | |||
|- | |||
! Sensitivity | |||
| 2 mA/mV or 10 mA/mV || 1 mA/Div to 1 A/Div<br/>(scope @ 50 mV/Div) | |||
| 1 mA/mV or 10 mA/mV || 1 mA/Div to 1 A/Div<br/>(scope @ 50 mV/Div) | |||
|- | |||
! Bandwidth (-3 dB) | |||
| 60 MHz @ 10 mA/mV || > 40 MHz | |||
| 200 MHz @ 10 mA/mV || > 70 MHz | |||
|- | |||
! LF limit (-3 dB) | |||
| 450 Hz @ 2 mA/mV<br/>120 Hz @ 10 mA/mV || < 12 Hz | |||
| 8500 Hz @ 1 mA/mV<br/>935 Hz @ 10 mA/mV || < 100 Hz | |||
|- | |||
! Maximum current | |||
| colspan="2" align="center" | 15 A<sub>p-p</sub> | |||
| colspan="2" align="center" | 6 A<sub>p-p</sub><br>(> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz) | |||
|} | |||
==Manuals== | ==Manuals== | ||
Line 17: | Line 33: | ||
* [http://w140.com/tek_p6022.pdf Tektronix P6022 Manual (PDF)] | * [http://w140.com/tek_p6022.pdf Tektronix P6022 Manual (PDF)] | ||
[[Category:Oscilloscope current probes]] | [[Category:Oscilloscope current probes]] | ||
[[Category:Introduced in 1969]] | [[Category:Introduced in 1969]] |
Revision as of 10:49, 15 June 2015
The Tektronix P6022 is an AC current probe for oscilloscopes. It can be used with the included passive termination, a type 134 current probe amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in. Bandwidth is at least 200 MHz with the passive termination.
The sister model P6021 has lower bandwidth but also a lower LF cut-off frequency and higher peak current rating.
Specifications
P6021 passive | P6021 + 134 | P6022 passive | P6022 + 134 | |
---|---|---|---|---|
Sensitivity | 2 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
1 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
Bandwidth (-3 dB) | 60 MHz @ 10 mA/mV | > 40 MHz | 200 MHz @ 10 mA/mV | > 70 MHz |
LF limit (-3 dB) | 450 Hz @ 2 mA/mV 120 Hz @ 10 mA/mV |
< 12 Hz | 8500 Hz @ 1 mA/mV 935 Hz @ 10 mA/mV |
< 100 Hz |
Maximum current | 15 Ap-p | 6 Ap-p (> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz) |