P6021: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
[[File:Tek-p6021.jpg|thumb|400px|right|P6021 with passive termination box]] | [[File:Tek-p6021.jpg|thumb|400px|right|P6021 with passive termination box]] | ||
The '''Tektronix P6021''' is | The '''Tektronix P6021''' is an AC current probe for oscilloscopes. It can be used with the included passive termination, a [[134|type 134 current probe amplifier]], or a [[3A9]] or [[7A14]] current probe amplifier scope plug-in. Bandwidth is up to 52 MHz. | ||
The sister model [[P6022]] has higher bandwidth but also a higher LF cut-off frequency and lower peak current rating. | The sister model [[P6022]] has higher bandwidth but also a higher LF cut-off frequency and lower peak current rating. |
Revision as of 10:50, 15 June 2015
The Tektronix P6021 is an AC current probe for oscilloscopes. It can be used with the included passive termination, a type 134 current probe amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in. Bandwidth is up to 52 MHz.
The sister model P6022 has higher bandwidth but also a higher LF cut-off frequency and lower peak current rating.
Specifications
P6021 passive | P6021 + 134 | P6022 passive | P6022 + 134 | |
---|---|---|---|---|
Sensitivity | 2 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
1 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
Bandwidth (-3 dB) | 60 MHz @ 10 mA/mV | > 40 MHz | 200 MHz @ 10 mA/mV | > 70 MHz |
LF limit (-3 dB) | 450 Hz @ 2 mA/mV 120 Hz @ 10 mA/mV |
< 12 Hz | 8500 Hz @ 1 mA/mV 935 Hz @ 10 mA/mV |
< 100 Hz |
Maximum current | 15 Ap-p | 6 Ap-p (> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz) |
Manuals
Pictures
-
Tektronix P6021 with passive termination box
-
P6021 catalog image