Template:Plugin Sidebar 2 The Tektronix S-2 Sampling Head plug-in provides a single GR-874 50 Ω input with a 75 ps risetime.
The S-2 can be used in the 7000 series and 3S series of sampling plug-ins. It provides an internal trigger pickoff signal for internal triggering. Noise is specified as less than 10 mV.
When the S-2 was first introduced, the rise-time specification was 50 ps, but that was not achieved in practice, so the rise-time specification was revised to be 75 ps.
Key Specifications
Rise time | 75 ps |
---|---|
Bandwidth | 4.66 GHz eq. |
Input voltage | -1 to +1 V (max. -5 to +5) |
Pictures
-
-
S-52 and S-2 give 76 ps rise-time together.
-
-
-
-
Sampling diodes in place.
-
Input termination resistor.
-
-
-
Diode holder slides out.
-
-
-
-
-