The '''Tektronix P6021''' is an AC current probe for oscilloscopes.  It can be used with the included passive termination, a [[134|type 134 current probe amplifier]], or a [[3A9]] or [[7A14]] current probe amplifier scope plug-in. Bandwidth is up to 52 MHz.
The '''Tektronix P6021''' is a 125-turn AC current probe for oscilloscopes.  It can be used with the included passive termination, a [[134|type 134 current probe amplifier]], or a [[3A9]] or [[7A14]] current probe amplifier scope plug-in. Bandwidth is up to 52 MHz.
[[File:P6021 circuit.jpg|right|thumb|350px|Schematic (click to enlarge)]]
[[File:P6021 circuit.jpg|right|thumb|350px|Schematic (click to enlarge)]]
The sister model [[P6022]] has higher bandwidth but also a higher LF cut-off frequency and lower peak current rating.
The sister model [[P6022]] has higher bandwidth but also a higher LF cut-off frequency and lower peak current rating.
Line 39: Line 39:
Tek-p6021.jpg | Tektronix P6021 with passive termination box  
Tek-p6021.jpg | Tektronix P6021 with passive termination box  
Tek-p6021-catalog.jpg | P6021 catalog image
Tek-p6021-catalog.jpg | P6021 catalog image
P6021-bat41-1.jpg | Measuring diode reverse recovery
P6021-bat41-2.jpg | BAT41 diode reverse recovery, 20 mA/Div
</gallery>
</gallery>
Comparison of P6022 with passive termination @ 10 mA/Div (top trace) vs. P6021+134 (bottom trace).
Comparison of P6022 with passive termination @ 10 mA/Div (top trace) vs. P6021+134 (bottom trace).

Revision as of 06:06, 26 October 2016

P6021 with passive termination box

The Tektronix P6021 is a 125-turn AC current probe for oscilloscopes. It can be used with the included passive termination, a type 134 current probe amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in. Bandwidth is up to 52 MHz.

Schematic (click to enlarge)

The sister model P6022 has higher bandwidth but also a higher LF cut-off frequency and lower peak current rating.

Specifications

P6021 passive P6021 + 134 P6022 passive P6022 + 134
Sensitivity 2 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
1 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
Bandwidth (-3 dB) 60 MHz @ 10 mA/mV > 40 MHz 200 MHz @ 10 mA/mV > 70 MHz
LF limit (-3 dB) 450 Hz @ 2 mA/mV
120 Hz @ 10 mA/mV
< 12 Hz 8500 Hz @ 1 mA/mV
935 Hz @ 10 mA/mV
< 100 Hz
Maximum current 15 Ap-p 6 Ap-p
(> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz)