1S2: Difference between revisions
No edit summary |
(fixed broken link etc.) |
||
Line 28: | Line 28: | ||
==Links== | ==Links== | ||
* [ | * [[Media:062-1244-00.pdf | Tektronix 062-1244-00: Time-Domain Reflectometry Measurement Concepts]], James A. Strickland, 1969. pages. PDF, OCR, 6.2 MB | ||
* [[Media:Service Scope 45 Aug 1967.pdf | Service Scope No. 45, August 1967]] | * [[Media:Service Scope 45 Aug 1967.pdf | Service Scope No. 45, August 1967 - Time-Domain Reflectometry Theory]] | ||
* [http://w140.com/kurt/50_years_sampling.pdf 50 Years of RF and Microwave Sampling, Mark Kahrs] | * [http://w140.com/kurt/50_years_sampling.pdf 50 Years of RF and Microwave Sampling, Mark Kahrs] | ||
* [http://www.picosecond.com/objects/AN-04.pdf Picosecond Pulse Labs Application Note 4: TDR] | * [http://www.picosecond.com/objects/AN-04.pdf Picosecond Pulse Labs Application Note 4: TDR] | ||
Line 36: | Line 36: | ||
<gallery> | <gallery> | ||
1s2_front.jpg|front view | |||
1s2_left.jpg|left side view | |||
1s2_right.jpg|right side view | |||
1s2_bottom.jpg|bottom view | |||
Tek 1s2 e 1.jpg|time mode | Tek 1s2 e 1.jpg|time mode | ||
Tek 1s2 e 2.jpg|distance mode | Tek 1s2 e 2.jpg|distance mode |
Revision as of 01:55, 6 March 2017
Template:Plugin Sidebar 2 The Tektronix 1S2 is a sampling/TDR plug-in for 500-series scopes. Like the 1S1, it is a complete sampling subsystem and uses the mainframe merely as a power supply and low-speed display.
Unlike the 1S1, it contains pulsers that allows it to perform time-domain reflectometry (TDR) measurements. The 1S2 has two 50 Ω pulsers, one of which is active at a time. One puts out a 250 mV pulse with 50 ps rise time. The other puts out a slower 1 V pulse. The sampling bridge is a feed-through type.
For TDR measurements, the signal from one of the internal pulsers is fed through the sampler, and out to the the transmission line being tested. Returning pulses are detected as they pass back through the sampler, and they are reabsorbed by the 50 Ω impedance of the pulser.
Waveform output can be to the CRT of the mainframe and/or to a plotter or low-speed data acquisition device via banana connectors on the front of the 1S2.
The 1S2 was introduced in 1967 and was sold through 1971 or 1972.
Links
- Tektronix 062-1244-00: Time-Domain Reflectometry Measurement Concepts, James A. Strickland, 1969. pages. PDF, OCR, 6.2 MB
- Service Scope No. 45, August 1967 - Time-Domain Reflectometry Theory
- 50 Years of RF and Microwave Sampling, Mark Kahrs
- Picosecond Pulse Labs Application Note 4: TDR
Pictures
-
front view
-
left side view
-
right side view
-
bottom view
-
time mode
-
distance mode
-
-
-
-
-