{{{manufacturer}}} 
10/100 MHz Digital Storage Scope
Tek 468

Produced from 1980 to 1985

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 468 is a digital/analog scope, essentially a 465B with an added 25 MS/s 8 bit digitizer.

Specifications

  • Digital mode: Sampling rate 25 MS/s, bandwidth 10 MHz (sine)/2.5 MHz (pulse), resolution 8 bit
  • Analog mode: 100 MHz bandwidth
  • GPIB option
  • please add more ...

Repair issues

Many 468s used Mostek MKB36000 masked ROMs that can suffer from "ROM rot". It may be necessary to replace the 160-0459-01 and 160-0759-01 ROMs with EPROMs.