The '''Tektronix Type 3B4''' is a timebase plug-in for [[560-series scopes]]. It was introduced in 1964. | The '''Tektronix Type 3B4''' is a timebase plug-in for [[560-series scopes]]. It was introduced in 1964. | ||
It was intended primarily for use with the 561A, but works fine in other 560-series scopes. The 3B4 is unusual in having an explicit "FREE RUN" mode. | It was intended primarily for use with the [[561A]], but works fine in other 560-series scopes. The 3B4 is unusual in having an explicit "FREE RUN" mode. | ||
In the triggered modes, the [[tunnel diodes|tunnel diode]]-based triggering is rated to work to 20 MHz. The vertical bandwidth of typical 560-series (non-sampling) scopes is about 10 MHz, so 20 MHz is adequate. | In the triggered modes, the [[tunnel diodes|tunnel diode]]-based triggering is rated to work to 20 MHz. The vertical bandwidth of typical 560-series (non-sampling) scopes is about 10 MHz, so 20 MHz is adequate. | ||
Line 29: | Line 29: | ||
<gallery> | <gallery> | ||
3b4_front.jpg|front view | |||
3b4_left.jpg|left side view | |||
3b4_right.jpg|right side view | |||
3b4_top.jpg|top view | |||
</gallery> | </gallery> | ||
[[Category:560 series plugins]] | [[Category:560 series plugins]] |
Revision as of 06:19, 13 October 2017
Template:Plugin Sidebar 2 The Tektronix Type 3B4 is a timebase plug-in for 560-series scopes. It was introduced in 1964.
It was intended primarily for use with the 561A, but works fine in other 560-series scopes. The 3B4 is unusual in having an explicit "FREE RUN" mode.
In the triggered modes, the tunnel diode-based triggering is rated to work to 20 MHz. The vertical bandwidth of typical 560-series (non-sampling) scopes is about 10 MHz, so 20 MHz is adequate.
Triggering is done with a TD3A 4.7 mA tunnel diode. The trigger input is amplified and buffered by a 6DJ8-based differential amplifier driving a common-emitter 2N964 germanium PNP transistor whose collector current switches the tunnel diode.
The 283 Real Time adapter enables real-time sweeps with a 3B4.
Key Specifications
- please add
Links
Pictures
-
front view
-
left side view
-
right side view
-
top view