{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Bandwidth | 300 MHz, Limit: 20, 100, Full }}
{{Spec | Bandwidth | 300 MHz, Limit: 20, 100, Full }}
{{Spec | Deflection| Two Channels With Simultaneous Acquisition with sampling rate: 500MSa/s. CH 1&2: 2mV/div to 5V/div in 1-2-5 sequence }}
{{Spec | Deflection| Two Channels With Simultaneous Acquisition with sampling rate: 500MSa/s Each. CH 1&2: 2mV/div to 5V/div in 1-2-5 sequence }}
{{Spec | Auto Scale Factor | On-Screen Readout indicates probe tip deflection factors for 1X, 10X, 100X and 1000X probes }}
{{Spec | Auto Scale Factor | On-Screen Readout indicates probe tip deflection factors for 1X, 10X, 100X and 1000X probes }}
{{Spec | Input Impedance| 1M, 15pF }}
{{Spec | Input Impedance| 1M, 15pF }}

Revision as of 23:37, 14 December 2018

{{{manufacturer}}} 
300 MHz, 500 MS/s 2-ch digital scope
Tektronix 2440

Produced from 1988 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 2440 is a two-channel 300 MHz digital sampling oscilloscope from the late 1980s. The maximum sample rate is 500 megasamples per second, per channel.

WARNING:
Operation of the 2440 (and 2432 and 2430): A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.

Key Specifications

Bandwidth 300 MHz, Limit: 20, 100, Full
Deflection Two Channels With Simultaneous Acquisition with sampling rate: 500MSa/s Each. CH 1&2: 2mV/div to 5V/div in 1-2-5 sequence
Auto Scale Factor On-Screen Readout indicates probe tip deflection factors for 1X, 10X, 100X and 1000X probes
Input Impedance 1M, 15pF
Sweep Speeds Modes A, A Intensified and B :2ns/div to 5s/div in 1-2-5 sequence
Auto Measure Simultaneously measures up to four parameters on one or more displayed waveforms, updated a 3hz intervals or display a snapshot of 20 parameters of waveform target
Acquisition Modes Normal, Envelope (glitch capture), Average
Display Modes CH1, CH2, invert, add, multiply, X-Y
Cursors Volts, Time, Volts At Time, 1/Time, Slope
Functions A Mode - Auto Level, Auto/Roll, Normal and Single Seq, B Mode - Trigger After Delay, Runs After Delay and many more too long to list here
Interface GPIB
Probes Two Passive Voltage 10X 1.3m P6137(400 MHz) Probes
Power 160 W, 115vac: 90 to 132vac, 230vac: 80 to 250vac, 48 to 440hz

Options

Links

Pictures