2465B: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
mNo edit summary
Line 24: Line 24:
CRT is the [[154-0850-01]].
CRT is the [[154-0850-01]].


The '''2467B''' is the same as the 2465B, except that the 2465B uses a conventional CRT while the 2467B uses a [[Micro-channel plate CRT]]. The MCP CRT enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.
The '''2467B''' is the same as the 2465B, except that the 2465B uses a conventional CRT while the 2467B uses a [[micro-channel plate CRT]]. The MCP CRT enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.


The 2465B is from the penultimate generation of analog Tektronix scopes.
The 2465B is from the penultimate generation of analog Tektronix scopes.

Revision as of 23:27, 26 April 2019

{{{manufacturer}}} 
Portable 200/250/400 MHz 4-ch scope
Tektronix 2465B

Produced from 1989 to (?)

Manuals
Manuals – Specifications – Links – Pictures


The Tektronix 2465B is a four-channel 400 MHz portable oscilloscope. The 2445B and 2455B are 200 and 250 MHz versions.

CRT is the 154-0850-01.

The 2467B is the same as the 2465B, except that the 2465B uses a conventional CRT while the 2467B uses a micro-channel plate CRT. The MCP CRT enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.

The 2465B is from the penultimate generation of analog Tektronix scopes.

The horizontal amplifier in the 2465B was designed by Art Metz and Ken Schlotzhauer. Art Metz also worked on the triggers. Art Metz and Walt Ainsworth designed the sweeps.

Options

  • Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
  • Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
  • Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
  • Option 09 added option 06, the CTT, plus a 17-bit P6407 word recognizer probe.
  • Option 10 added a GPIB interface for remote control.
  • Option 11 added two probe-power connectors on the rear panel of the instrument. Only shown in the 1989 catalogue.
  • Option 46 is the designation for the military version of the scope (OS-288/G) that included option 10 IEEE-488 interface and 2 probes.

Key Specifications

     — 2445B
Bandwidth 200 MHz
     — 2455B
Bandwidth 250 MHz
     — 2465B
Bandwidth 400 MHz
     — 2466B
Bandwidth 400 MHz
     — 2467B
Bandwidth 400 MHz
     — Common
Sweep Rate 500 ps/div
Channels Four independent channels
Vertical 2 mV/div vertical sensitivity
Cursors Delta Volts and Delta Time Cursors
CRT Readout Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators
Trigger Advanced Triggering with "Hands Off" Auto Level Triggering
Trigger Bandwidth 500 MHz min.
Input Impedance 50 Ω/1 MΩ inputs with 50 Ω protection
Probes Two or four P6137 ×10 probes, 1.3 m

Prices

1990: $13,045 (2467B) = $24,400 equivalent in 2017

See also

Links

Pictures

2455B

2465B

2465BDV

2467B