Pacific Measurements 1038: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar | | {{Oscilloscope Sidebar | | ||
title=Pacific Measurements 1038 | | title=Pacific Measurements 1038 | | ||
summary= | summary=100 kHz to 18.5 GHz network analyzer | | ||
image=Pacific Measurements 1038.jpg | | image=Pacific Measurements 1038.jpg | | ||
caption=Pacific Measurements 1038 with Tek D11 display, PM-H13 and x2 PM-V12 plug-ins | | caption=Pacific Measurements 1038 with Tek D11 display, PM-H13 and x2 PM-V12 plug-ins | | ||
Line 21: | Line 21: | ||
* [[Media:PM_POWER_DETECTORS_MODEL_1038_specs.jpg|PM Power Detectors Model 1038 Specifications (PDF), courtesy of Sphere Research]] | * [[Media:PM_POWER_DETECTORS_MODEL_1038_specs.jpg|PM Power Detectors Model 1038 Specifications (PDF), courtesy of Sphere Research]] | ||
}} | }} | ||
The '''Pacific Measurements 1038''' is a 1 or 2 channel scalar network analyzer | The '''Pacific Measurements 1038''' is a 1 or 2 channel scalar network analyzer, some models of which incorporate a [[5000-series scopes|Tektronix 5000-series display unit]] − | ||
a [[5110|D10 long-persistance display]] (P-7 phosphor) or a [[5111|D11 split-screen storage display]]. | |||
[[5111 | D11 split-screen storage]] | |||
The PM1038-D14 has a display unit with digital storage. From manual photos and diagrams, the D14 would appear not to be a Tek OEM unit (see also [[Introduction to the 5000-Series Oscilloscopes]] regarding 5114/D14). | |||
The PM1038 had an optional [[GPIB interface]] and was available in benchtop or rackmount configurations. | |||
Options: | Options: | ||
* Horizontal plug-ins H10 (sweep drive), H11 (sweep Drive and memory address circuits), H12 (sweep drive and ratio channel), H13 (sweep drive, memory address circuits and ratio channel) and K11 (replaces H11 and provides amplitude sweep). | * Horizontal plug-ins: H10 (sweep drive), H11 (sweep Drive and memory address circuits), H12 (sweep drive and ratio channel), H13 (sweep drive, memory address circuits and ratio channel) and K11 (replaces H11 and provides amplitude sweep). | ||
* Vertical plug-ins V10 (log amp and signal conditioning), V11 (log amp, signal conditioning and 256 point memory), V12 (log amp, signal conditioning and 1024 point memory), V13 (log amp, signal conditioning, recording of two calibration curves and 1024 point memory) and V20 (linear amp, 1024 point memory and for use in conjunction with Model 1018B power meter). | * Vertical plug-ins: V10 (log amp and signal conditioning), V11 (log amp, signal conditioning and 256 point memory), V12 (log amp, signal conditioning and 1024 point memory), V13 (log amp, signal conditioning, recording of two calibration curves and 1024 point memory) and V20 (linear amp, 1024 point memory and for use in conjunction with Model 1018B power meter). | ||
* N10 plug-in (dual channel network analyzer) | * N10 plug-in (dual channel network analyzer) | ||
* NS20 plug-in (dual channel network analyzer) with optional NS201 (2 to 18.5 GHz RF source) | * NS20 plug-in (dual channel network analyzer) with optional NS201 (2 to 18.5 GHz RF source) | ||
* C10 plug-in calibration fixture and extender kit for direct calibration and check-out of the D14/D14A Mainframe. It has extension cables to permit calibration and maintenance of the H/V system plug-ins | * C10 plug-in calibration fixture and extender kit for direct calibration and check-out of the D14/D14A Mainframe. It has extension cables to permit calibration and maintenance of the H/V system plug-ins | ||
* Power input calibrator unit (detector simulator - P/N 15484) will act as a "standard" detector to furnish accurate voltages to the H/V system when it is desired to calibrate the amplitude correction circuitry | * Power input calibrator unit (detector simulator - P/N 15484) will act as a "standard" detector to furnish accurate voltages to the H/V system when it is desired to calibrate the amplitude correction circuitry | ||
Pacific Measurements later became part of [[Wavetek]]. | Pacific Measurements later became part of [[Wavetek]]. | ||
Line 74: | Line 76: | ||
==Pictures == | ==Pictures == | ||
===1038-D10 | ===1038-D10=== | ||
<gallery> | <gallery> | ||
D10_Mainframe_PM1038_System.jpg | 1038-D10 H/V bench model | D10_Mainframe_PM1038_System.jpg | 1038-D10 H/V bench model with H13 and V11 plug-ins | ||
D10_Mainframe_rackmount_PM1038_System.jpg | 1038-D10 H/V rack model | D10_Mainframe_rackmount_PM1038_System.jpg | 1038-D10 H/V rack model with H13 and two V12 plug-ins | ||
D10_Mainframe_rackmount_PM1038_System_rear.jpg | 1038-D10 rack model, rear | D10_Mainframe_rackmount_PM1038_System_rear.jpg | 1038-D10 rack model, rear | ||
</gallery > | </gallery > | ||
===1038-D11 | ===1038-D11=== | ||
<gallery> | <gallery> | ||
Pacific Measurements 1038.jpg | 1038-D11 H/V bench model | Pacific Measurements 1038.jpg | 1038-D11 H/V bench model with H13 and two V12 plug-ins | ||
Pacific Measurements 1038 rear.jpg | 1038-D11 bench model, rear | Pacific Measurements 1038 rear.jpg | 1038-D11 bench model, rear | ||
</gallery > | </gallery > | ||
===1038-D14 | ===1038-D14=== | ||
<gallery> | <gallery> | ||
PacificMeasurements_1038_D14_H13_V12_front.jpg | 1038-D14 H/V bench model | PacificMeasurements_1038_D14_H13_V12_front.jpg | 1038-D14 H/V bench model with H13 and two V12 plug-ins | ||
PacificMeasurements_1038_D14_H13_V12_rear.jpg | 1038-D14 bench model, rear | PacificMeasurements_1038_D14_H13_V12_rear.jpg | 1038-D14 bench model, rear | ||
</gallery > | </gallery > | ||
===1038-D14A | ===1038-D14A=== | ||
<gallery> | <gallery> | ||
WavetekD14A_PM1038-N10_front.jpg | 1038-D14A N10 rack model | WavetekD14A_PM1038-N10_front.jpg | 1038-D14A N10 rack model with N10 plug-in | ||
WavetekD14A_PM1038-N10_back.jpg | 1038-D14A rack model, rear | WavetekD14A_PM1038-N10_back.jpg | 1038-D14A rack model, rear | ||
</gallery > | </gallery > | ||
===1038-D14 | ===1038-D14=== | ||
<gallery> | <gallery> | ||
1038_NS20_1200x900_cropped.jpg | 1038-D14 | 1038_NS20_1200x900_cropped.jpg | 1038-D14 bench model with NS20 plug-in | ||
</gallery > | </gallery > | ||
Revision as of 00:21, 4 May 2019
The Pacific Measurements 1038 is a 1 or 2 channel scalar network analyzer, some models of which incorporate a Tektronix 5000-series display unit − a D10 long-persistance display (P-7 phosphor) or a D11 split-screen storage display.
The PM1038-D14 has a display unit with digital storage. From manual photos and diagrams, the D14 would appear not to be a Tek OEM unit (see also Introduction to the 5000-Series Oscilloscopes regarding 5114/D14).
The PM1038 had an optional GPIB interface and was available in benchtop or rackmount configurations.
Options:
- Horizontal plug-ins: H10 (sweep drive), H11 (sweep Drive and memory address circuits), H12 (sweep drive and ratio channel), H13 (sweep drive, memory address circuits and ratio channel) and K11 (replaces H11 and provides amplitude sweep).
- Vertical plug-ins: V10 (log amp and signal conditioning), V11 (log amp, signal conditioning and 256 point memory), V12 (log amp, signal conditioning and 1024 point memory), V13 (log amp, signal conditioning, recording of two calibration curves and 1024 point memory) and V20 (linear amp, 1024 point memory and for use in conjunction with Model 1018B power meter).
- N10 plug-in (dual channel network analyzer)
- NS20 plug-in (dual channel network analyzer) with optional NS201 (2 to 18.5 GHz RF source)
- C10 plug-in calibration fixture and extender kit for direct calibration and check-out of the D14/D14A Mainframe. It has extension cables to permit calibration and maintenance of the H/V system plug-ins
- Power input calibrator unit (detector simulator - P/N 15484) will act as a "standard" detector to furnish accurate voltages to the H/V system when it is desired to calibrate the amplitude correction circuitry
Pacific Measurements later became part of Wavetek.
Key Specifications
— H/V System — | |
Offset Range | ±99.9 dB, 3 digits resolution, accuracy ±0.02 dB/10 dB ±0.05 dB |
Drift | @ 0 dBm, <0.01 dB/°C (+15° to +45°C ); @ −40 dBm, <0.5 dB/24 Hrs at constant temperature ) |
Frequency Range | 100 kHz to 18.5 GHz ; with single diode (P/N 12685, 12882, 12883, 13161) detector, 100 kHz to 1 GHz or (P/N 13160) 2 GHz ; with single diode (P/N 15272) or balanced (P/N 15285) detector, 1 MHz to 26.5 GHz ; Wavetek Pacific Measurements waveguide detector (P/N 15882), 26.5 GHz to 40.0 GHz ; other waveguide manufacturers, up to 110 GHz |
Power | −50 dBm to +10 dBm |
Dynamic Range | 60 dB (Reference Channel: 40 dB) |
Reading | Insertion Loss/Gain and Return Loss, 0.02 dB resolution |
Noise Floor | −70 dB |
Power | Approx. 100 VA @ 50 − 440 Hz; 100, 120, 240 VAC ±10% |
Dimensions | benchtop (H x W x D) 381 x 216 x 483 mm (15 x 8.5 x 19 in.); rackmount (H x W x D) 178 x 483 x 483 mm (7 x 19 x 19 in.) |
Weight | 18.2 kg (40 lbs) - vertical plug-in 2.3 kg (5 lbs), horizontal plug-in 2 kg (4.4 lbs) |
— Power Detectors (P/Ns 15272, 13782 and 13783 unless noted) — | |
Input Impedance | 50 Ω nominal; 75 Ω (P/N 12685, 12882, 13161) |
Input Power | max. +23 dBm (200 mV) peak or average |
Return Loss | >20.8 dB, SWR <1.20 from 100 kHz to 1 GHz (P/N 12685, 12882, 12883, 13160, 13161); >25.0 dB, SWR <1.12 from 1 MHz to 1 GHz; >18.0 dB, SWR <1.29 from 2 GHz to 12.4 GHz; >14.0 dB, SWR <1.50 up to 26.5 GHz |
Accuracy | 3% to 18.5 GHz and 5% to 26.5 GHz |
Flatness | ±0.5 dB to 18.5 GHz (P/N 15272); ±1.0 dB 18.5 GHz to 26.5 GHz (P/N 15272) ; ±1.0 dB to 18.5 GHz (P/N 13782) ; ±1.0 dB to 18.5 GHz (P/N 13783; ±2.0 dB with type N or APC7 connectors to 18 GHz, ±2.0 dB to 26.5 GHz with APC3.5 connectors |
— Power Detector P/N 15882 — | |
Input Power | max. +20 dBm (100 mV) peak or average |
Return Loss | >10 dB, SWR <1.92 from 26.5 to 40 GHz |
Accuracy | 5% from 26.5 to 40 GHz |
Flatness | ±2.0 dB from 26.5 to 40 GHz |
Temperature | 0° to 50°C operating, −50° to +65°C non-operating |
Accuracy | 0.2 dB to 2 dB from 30 MHz to 26.5 GHz, 0.5 dB to 2 dB from 26.5 GHz to 40 GHz |
Cable Length | 1.5 m (5 ft) |
Weight | Approx. 230 g (8 oz) |
Prices
Please add
Links
- RF Analyzers @ Sphere Research
- OE2IGL: "MAR104 - Mobile Amateur Rain Radar" Project with Return Loss Measurement Example
Pictures
1038-D10
-
1038-D10 H/V bench model with H13 and V11 plug-ins
-
1038-D10 H/V rack model with H13 and two V12 plug-ins
-
1038-D10 rack model, rear
1038-D11
-
1038-D11 H/V bench model with H13 and two V12 plug-ins
-
1038-D11 bench model, rear
1038-D14
-
1038-D14 H/V bench model with H13 and two V12 plug-ins
-
1038-D14 bench model, rear
1038-D14A
-
1038-D14A N10 rack model with N10 plug-in
-
1038-D14A rack model, rear
1038-D14
-
1038-D14 bench model with NS20 plug-in
1038-NS201
-
1038-NS201
-
1038-NS201 rear
-
1038-NS201
-
1038-NS201 rear