585/Repairs: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Created page with "==Time base inoperative== :'''Symptom:''' No trace :'''Root cause:''' Lead of neon bulb in Miller integrator (B171?) broken :'''Solution:''' Solder replacement lead after grin...")
 
No edit summary
Line 1: Line 1:
==Supplies out of regulation==
:'''Symptom:''' Several supplies out of regulation
:'''Root cause:''' dry HV electrolytics
:'''Solution:''' Rebuild caps using modern replacements
:<gallery>
Electrolytic repair 1.jpg | Remove defective cap
Electrolytic repair 2.jpg | Cut can near base, remove guts
Electrolytic repair 3.jpg | Fit modern cap
Electrolytic repair 4.jpg | Epoxy cap onto base
</gallery>
:--[[User:Peter|Peter]] ([[User talk:Peter|talk]]) 02:45, 4 May 2019 (PDT)
==HV low and trace invisible==
:'''Symptom:''' No trace, HV low despite maximum setting
:'''Root cause:''' HV [[Bumble Bee capacitors|PIO "Bumble Bee" capacitors]] leaky (~180 μA at 2 kV)
:'''Solution:''' Replace caps
:<gallery>
585 HV caps old.jpg | old PIO caps in place
Black Beauty caps.jpg | old PIO caps removed
585 HV caps new.jpg | new ceramic caps
</gallery>
:--[[User:Peter|Peter]] ([[User talk:Peter|talk]]) 02:45, 4 May 2019 (PDT)
==No trace==
:'''Symptom:''' Trace invisible
:'''Root cause:''' Wiper of focus pot not in contact
:'''Solution:''' Disassemble focus pot, clean and re-seat wiper
:--[[User:Peter|Peter]] ([[User talk:Peter|talk]]) 02:45, 4 May 2019 (PDT)
==Trace disappearing==
:'''Symptom:''' Trace fading after ~10 minutes operation
:'''Root cause:''' HV resonant cap (C808) leaky, overheating (visible bulge)
:'''Solution:''' Replace cap
:<gallery>
</gallery>
:--[[User:Peter|Peter]] ([[User talk:Peter|talk]]) 02:45, 4 May 2019 (PDT)
==Time base inoperative==
==Time base inoperative==
:'''Symptom:''' No trace
:'''Symptom:''' No trace
Line 4: Line 38:
:'''Solution:''' Solder replacement lead after grinding away some glass (or replace neon)
:'''Solution:''' Solder replacement lead after grinding away some glass (or replace neon)
:<gallery>
:<gallery>
585-neon-1.jpg
585-neon-1.jpg | broken lead
585-neon-2.jpg
585-neon-2.jpg | repaired leads (before encapsulation with epoxy)
</gallery>
</gallery>
:--[[User:Peter|Peter]] ([[User talk:Peter|talk]]) 02:16, 4 May 2019 (PDT)
:--[[User:Peter|Peter]] ([[User talk:Peter|talk]]) 02:45, 4 May 2019 (PDT)

Revision as of 02:45, 4 May 2019

Supplies out of regulation

Symptom: Several supplies out of regulation
Root cause: dry HV electrolytics
Solution: Rebuild caps using modern replacements
  • Remove defective cap

    Remove defective cap

  • Cut can near base, remove guts

    Cut can near base, remove guts

  • Fit modern cap

    Fit modern cap

  • Epoxy cap onto base

    Epoxy cap onto base

  • --Peter (talk) 02:45, 4 May 2019 (PDT)

    HV low and trace invisible

    Symptom: No trace, HV low despite maximum setting
    Root cause: HV PIO "Bumble Bee" capacitors leaky (~180 μA at 2 kV)
    Solution: Replace caps
  • old PIO caps in place

    old PIO caps in place

  • old PIO caps removed

    old PIO caps removed

  • new ceramic caps

    new ceramic caps

  • --Peter (talk) 02:45, 4 May 2019 (PDT)

    No trace

    Symptom: Trace invisible
    Root cause: Wiper of focus pot not in contact
    Solution: Disassemble focus pot, clean and re-seat wiper
    --Peter (talk) 02:45, 4 May 2019 (PDT)

    Trace disappearing

    Symptom: Trace fading after ~10 minutes operation
    Root cause: HV resonant cap (C808) leaky, overheating (visible bulge)
    Solution: Replace cap
    --Peter (talk) 02:45, 4 May 2019 (PDT)

    Time base inoperative

    Symptom: No trace
    Root cause: Lead of neon bulb in Miller integrator (B171?) broken
    Solution: Solder replacement lead after grinding away some glass (or replace neon)
  • broken lead

    broken lead

  • repaired leads (before encapsulation with epoxy)

    repaired leads (before encapsulation with epoxy)

  • --Peter (talk) 02:45, 4 May 2019 (PDT)