2641: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Created page with "The '''Tektronix 2641''' is an FFT-based signal analysis instrument. {{MissingSpecs}} ==Manuals== * Category:Manual needed ''Manual needed - please add'' {{MissingPics}...")
 
No edit summary
Line 1: Line 1:
The '''Tektronix 2641''' is an FFT-based signal analysis instrument.
{{Oscilloscope Sidebar |
title=Tektronix 2641 |
summary=Fourier Analyzer DC to 100 kHz |
image= Tek_2641_1.JPG |
caption=Tektronix 2641 |
introduced=1991 |
discontinued=1993 |
manuals=
Need User Guide and Service Manual
* [[Media: Tek_2600_Series_Catalog_1991.pdf| Tektronix 2641 Final Spec (PDF)]]
}}


{{MissingSpecs}}
The '''Tektronix 2641''' is a Fourier analyzer that links dedicated signal acquisition and analysis with a personal computer’s mass storage and graphics.  It allows measurement solutions for electrical, mechanical, and electromechanical applications in the DC to 100 kHz frequency range.  Typical applications are Structural Analysis, Control Systems, Machine Vibration, Audio and Acoustic Tests, and General Purpose Signal and System Analysis.


==Manuals==
Each of the channel inputs provide simultaneous sampling of all channels utilizing 12 bit ADC standard or 16 bit ADC optionally.  Signal processing includes Fourier Transform (FFT) and Spectral Lines.  The signal generator has a wide variety of functions, like sine, square, sawtooth, triangle, input, random, adjustable random, chirp, and arbitrary.  With the optional TurboPac Application Library and Run-Time License advanced measurement calculations and graphs can be generated from the data collected.
* [[Category:Manual needed]] ''Manual needed - please add''


{{MissingPics}}
The PC’s monitor displays the measurements results – but that’s where the Fourier Analyzer dependence on the PC stops.  All of the data acquisition, data management, signal processing and other computationally intensive operations are reserved for the Fourier Analyzer’s high-performance measurement and analysis hardware.  Built-in analog and digital anti-alias filters automatically track all of the bandwidth settings.  A selection of frame sizes allows the user to choose the best trade-off between acquisition time and frequency resolution.  When high frequency resolution around a specific signal is needed, the option "zoom" feature can be used.  It allows one to focus up to 1600 spectral line with a span as small as 10 Hz about the frequency of interest.


[[Category:Spectrum Analyzers]]
'''[[wikipedia:Fast_Fourier_transform|Fast Fourier transform]]''' (FFT) is an algorithm that computes the [[wikipedia:Discrete_Fourier_transform|descrete Fourier transform]] (DFT) of a sequence, or its inverse (IDFT).  [[Wikipedia:Fourier_analysis|Fourier analysis]] converts a signal from its original domain (often time or space) to a representation in the [[Wikipedia:Frequency_domain|frequency domain]] and vice versa..
 
[[File:FFT_of_Cosine_Summation_Function.png|center|500px|Fourier analysis]]
 
Front panel inputs/outputs are: CH1, CH2, CH3, and CH4 each with a [[BNC connector]] (1 MΩ; 200 pF; ±30 V); and OUTPUT [[BNC connector]] (50Ω; ±10 V; signal general output capable of a variety of pre-defined, as well as user-defined, signals.)
 
Rear panel inputs/outputs are: SYSTEM INTERCONNECT [[DB9 connector]] (Male connector used for both External triggering, and External sampling inputs.  All pins TTL-level except Signal ground: Pin 1 triggering signal input; pin 2 trigger sense output; pin 3 external clock input; pins 6 thru 8 signal ground; pin 9 is the external sampling input); and SERIAL PORT [[BNC connector]] (Female connector used linking to the host computer via a Tektronix supplied serial interface cable).
 
---------------------------------------------------------
<div style='text-align: center;'>Specifications based on 2000 published documentation, unless otherwise specified.</div>
{{BeginSpecs}}
{{Spec | Frequency Ranges | DC to 100 kHz }}
{{Spec | Max Real-time Bandwidth | 10 kHz }}
{{Spec | Dynamic Range | 75 dB }}
{{Spec | Standard Channels | 2 }}
{{Spec | Max Channels | 4 }}
{{Spec | Channel Match | ±0.075 dB (DC to 50 kHz) }}
{{Spec | Transient Capture Samples | 500 K }}
{{Spec | Spectral Lines | 25 to 1600 }}
{{Spec | Input Impedance | 1 MΩ; 200 pF }}
{{Spec | Max Input Level | ±30 V }}
{{Spec | Included Accessories | User Guide; Instrument Program Software; System Simulator Box; Power Cord; and Serial Interface Cable (please specify) }}
{{Spec | Weight | Standard accessories: 11.8 kg (26 lbs) }}
{{Spec | Power | 90 − 250 V<sub>AC</sub>, 48 to 66 Hz, >120 W }}
{{Spec | Operating Atmospherics | Temperatures: 0 °C to +50 °C; Humidity: 95% for five days; Altitude: Up to 4.8 km (15,000 ft) }}
{{EndSpecs}}
 
==Options==
* Opt. 1H: Four Input Channels
* Opt. 2H: 2-CH Zoom
* Opt. 3H: 4-CH Zoom
* Opt. 4H: Signal Generator
 
==Pictures==
<gallery>
Tek_2641_1.JPG
</gallery>
 
[[Category: Spectrum Analyzers]]

Revision as of 17:40, 15 July 2019

{{{manufacturer}}} 
Fourier Analyzer DC to 100 kHz
Tektronix 2641

Produced from 1991 to 1993

Manuals

Need User Guide and Service Manual

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures


The Tektronix 2641 is a Fourier analyzer that links dedicated signal acquisition and analysis with a personal computer’s mass storage and graphics. It allows measurement solutions for electrical, mechanical, and electromechanical applications in the DC to 100 kHz frequency range. Typical applications are Structural Analysis, Control Systems, Machine Vibration, Audio and Acoustic Tests, and General Purpose Signal and System Analysis.

Each of the channel inputs provide simultaneous sampling of all channels utilizing 12 bit ADC standard or 16 bit ADC optionally. Signal processing includes Fourier Transform (FFT) and Spectral Lines. The signal generator has a wide variety of functions, like sine, square, sawtooth, triangle, input, random, adjustable random, chirp, and arbitrary. With the optional TurboPac Application Library and Run-Time License advanced measurement calculations and graphs can be generated from the data collected.

The PC’s monitor displays the measurements results – but that’s where the Fourier Analyzer dependence on the PC stops. All of the data acquisition, data management, signal processing and other computationally intensive operations are reserved for the Fourier Analyzer’s high-performance measurement and analysis hardware. Built-in analog and digital anti-alias filters automatically track all of the bandwidth settings. A selection of frame sizes allows the user to choose the best trade-off between acquisition time and frequency resolution. When high frequency resolution around a specific signal is needed, the option "zoom" feature can be used. It allows one to focus up to 1600 spectral line with a span as small as 10 Hz about the frequency of interest.

Fast Fourier transform (FFT) is an algorithm that computes the descrete Fourier transform (DFT) of a sequence, or its inverse (IDFT). Fourier analysis converts a signal from its original domain (often time or space) to a representation in the frequency domain and vice versa..

Fourier analysis
Fourier analysis

Front panel inputs/outputs are: CH1, CH2, CH3, and CH4 each with a BNC connector (1 MΩ; 200 pF; ±30 V); and OUTPUT BNC connector (50Ω; ±10 V; signal general output capable of a variety of pre-defined, as well as user-defined, signals.)

Rear panel inputs/outputs are: SYSTEM INTERCONNECT DB9 connector (Male connector used for both External triggering, and External sampling inputs. All pins TTL-level except Signal ground: Pin 1 triggering signal input; pin 2 trigger sense output; pin 3 external clock input; pins 6 thru 8 signal ground; pin 9 is the external sampling input); and SERIAL PORT BNC connector (Female connector used linking to the host computer via a Tektronix supplied serial interface cable).


Specifications based on 2000 published documentation, unless otherwise specified.

Key Specifications

Frequency Ranges DC to 100 kHz
Max Real-time Bandwidth 10 kHz
Dynamic Range 75 dB
Standard Channels 2
Max Channels 4
Channel Match ±0.075 dB (DC to 50 kHz)
Transient Capture Samples 500 K
Spectral Lines 25 to 1600
Input Impedance 1 MΩ; 200 pF
Max Input Level ±30 V
Included Accessories User Guide; Instrument Program Software; System Simulator Box; Power Cord; and Serial Interface Cable (please specify)
Weight Standard accessories: 11.8 kg (26 lbs)
Power 90 − 250 VAC, 48 to 66 Hz, >120 W
Operating Atmospherics Temperatures: 0 °C to +50 °C; Humidity: 95% for five days; Altitude: Up to 4.8 km (15,000 ft)

Options

  • Opt. 1H: Four Input Channels
  • Opt. 2H: 2-CH Zoom
  • Opt. 3H: 4-CH Zoom
  • Opt. 4H: Signal Generator

Pictures