Passive Probes: Difference between revisions
Jump to navigation
Jump to search
(Created page with "This Table is based on the [http://w140.com/tek_probe_crossref_1990.pdf| Tek Probe Cross-Reference]. Please expand. {| class="wikitable" !colspan="9"|Specification Summary |-...") |
No edit summary |
||
Line 23: | Line 23: | ||
|- | |- | ||
|[[P6015]] || 1000x || 10ft. || 100||3.0||75||20 kV||12-47||N | |[[P6015]] || 1000x || 10ft. || 100||3.0||75||20 kV||12-47||N | ||
|- | |||
|[[P6053B]] || 10x || 6ft. || 10||12.5||200||500 V||15-24||Y | |||
|- | |||
|[[P6055]] || 10x || 3.5ft. || 1||10||60||500 V||12-47||Y | |||
|} | |} |
Revision as of 17:43, 3 April 2020
This Table is based on the Tek Probe Cross-Reference. Please expand.
Specification Summary | ||||||||
---|---|---|---|---|---|---|---|---|
Model | Attenuation | Length | Loading | Bandwidth MHz |
Max. Voltage | Compensation Range pF |
Readout | |
Input R / MΩ | Input C / pF | |||||||
P6007 | 100x | 6ft. | 10 | 2.2 | 25 | 1.5 kV | 15-55 | N |
P6009 | 100x | 9ft. | 10 | 2.5 | 120 | 1.5 kV | 15-47 | Y |
P6009 Opt. 14 | 100x | 9ft. | 10 | 2.5 | 120 | 1.5 kV | 15-47 | N |
P6015 | 1000x | 10ft. | 100 | 3.0 | 75 | 20 kV | 12-47 | N |
P6053B | 10x | 6ft. | 10 | 12.5 | 200 | 500 V | 15-24 | Y |
P6055 | 10x | 3.5ft. | 1 | 10 | 60 | 500 V | 12-47 | Y |