CA: Difference between revisions
No edit summary |
(Manual OCRed) |
||
Line 8: | Line 8: | ||
series=[[500-series scopes]]| | series=[[500-series scopes]]| | ||
manuals= | manuals= | ||
* [[Media:070-318.pdf|Tektronix Type CA Manual]] (PDF, OCR) | |||
* [[Media:tek_type_ca_fcp.pdf|Tektronix Type CA Factory Calibration Procedure]] (PDF, OCR) | |||
* [[Media:Tek type ca fcp april 1967.pdf|Tektronix Type CA Factory Calibration Procedure, April 1967]] | |||
<small> | |||
'''Alternate''' | |||
* [http://bama.edebris.com/download/tek/ca/ca.djvu Tektronix Type CA Manual (DjVu)] | * [http://bama.edebris.com/download/tek/ca/ca.djvu Tektronix Type CA Manual (DjVu)] | ||
</small> | |||
}} | }} | ||
The '''Tektronix Type CA''' is the most common plug-in for [[500-series scopes]]. | The '''Tektronix Type CA''' is the most common plug-in for [[500-series scopes]]. |
Revision as of 05:08, 1 February 2021
Template:Plugin Sidebar 2 The Tektronix Type CA is the most common plug-in for 500-series scopes. Over 50,000 were produced.
The risetime of a Type 545 oscilloscope with a Type CA plug-in is 15 nanoseconds, and the bandwidth is 24 MHz. Maximum vertical sensitivity is 50 mV/div.
Type CA is an enhancement over its predecessor, Type 53/54C, adding ADDED mode to the A, B, CHOPPED, ALT repertoire. The "A" in "CA" stands not only for the fact that it is a modified, enhanced replacement, but also because the feature added was "ADDED". It was introduced in 1959 and discontinued in 1973, making it not only the most-produced but also one of the longest-lived.
Late versions have BNC connectors instead of UHF connectors.
Lavoie Laboratories produced an unauthorized clone, the Lavoie LA-265-CA.
Specifications
please add
Pictures
-
front view
-
left view
-
right view
-
top view
-
bottom view
-
schematic
-