The '''Tektronix P6156''' is a DC to 3.5 GHz, compact size, fast-rise, low input capacitance, passive voltage probe with a constant input resistance over a wide range of frequencies. It is designed for use with wide band oscilloscope amplifiers with 50 Ω inputs, such as the Tektronix [[11000-series scopes]] with the [[11A71]] plug-in.  
The '''Tektronix P6156''' is a DC to 3.5 GHz, compact size, fast-rise, low input capacitance, passive voltage probe with a constant input resistance over a wide range of frequencies. It is designed for use with wide band oscilloscope amplifiers with 50 Ω inputs, such as the Tektronix [[11000-series scopes]] with the [[11A71]] plug-in.  


Options were available for ×1, ×10, ×20 or ×100 attenuation (×1 and ×100 versions with 1.5 GHz bandwidth), with attenuator tips color coded for identification.  
Options were available for ×1 (Opt. 27), ×10, ×20 (Opt.26) or ×100 (Opt.25) attenuation (×1 and ×100 versions with 1.5 GHz bandwidth), with attenuator tips color coded for identification.  
The termination box has a switch that sets the readout resistor accordingly (×20 is recognized only on 11000 series, not on 7000).
The termination box has a switch that sets the readout resistor accordingly (×20 is recognized only on 11000 series, not on 7000).



Revision as of 05:25, 23 May 2021

The Tektronix P6156 is a DC to 3.5 GHz, compact size, fast-rise, low input capacitance, passive voltage probe with a constant input resistance over a wide range of frequencies. It is designed for use with wide band oscilloscope amplifiers with 50 Ω inputs, such as the Tektronix 11000-series scopes with the 11A71 plug-in.

Options were available for ×1 (Opt. 27), ×10, ×20 (Opt.26) or ×100 (Opt.25) attenuation (×1 and ×100 versions with 1.5 GHz bandwidth), with attenuator tips color coded for identification. The termination box has a switch that sets the readout resistor accordingly (×20 is recognized only on 11000 series, not on 7000).

An “identify” button on the probe head provides trace identity and allows control of one or more programmable functions in 11000 Series oscilloscopes.

The P6156 is equipped with a BNC connector that provides trace identify and digital readout information.

Specifications

Model ×1 ×10 ×20 ×100
Input Impedance 50 Ω 500 Ω // ≤1 pF 1 kΩ // ≤1 pF 5 kΩ // ≤2.1 pF
Max. Input 15 VRMS 15 VRMS 22 VRMS 50 VRMS
Bandwidth ≥1.5 GHz ≥3.5 GHz ≥3.5 GHz ≥1.5 GHz
Rise Time ≤300 ps ≤100 ps ≤100 ps ≤233 ps