CA: Difference between revisions
m (→top: clean up, replaced: title=Tektronix → manufacturer=Tektronix | model=) |
No edit summary |
||
Line 1: | Line 1: | ||
{{Plugin Sidebar 2| | {{Plugin Sidebar 2 | ||
manufacturer=Tektronix | | |manufacturer=Tektronix | ||
summary=24 MHz dual-channel amplifier| | |series=500-series scopes | ||
image=Tek Type CA front.jpg | | |type=Type CA | ||
caption=Type CA front view| | |summary=24 MHz dual-channel amplifier | ||
introduced=1959 | | |image=Tek Type CA front.jpg | ||
discontinued=1973 | | |caption=Type CA front view | ||
|introduced=1959 | |||
manuals= | |discontinued=1973 | ||
|designers= | |||
|manuals= | |||
* [[Media:070-318.pdf|Tektronix Type CA Manual]] (PDF, OCR) | * [[Media:070-318.pdf|Tektronix Type CA Manual]] (PDF, OCR) | ||
* [[Media:tek_type_ca_fcp.pdf|Tektronix Type CA Factory Calibration Procedure]] (PDF, OCR) | * [[Media:tek_type_ca_fcp.pdf|Tektronix Type CA Factory Calibration Procedure]] (PDF, OCR) | ||
Line 17: | Line 19: | ||
</small> | </small> | ||
}} | }} | ||
The '''Tektronix Type CA''' is the most common plug-in for [[500-series scopes]] | The '''Tektronix Type CA''' is the most common plug-in for [[500-series scopes]] – over 50,000 were produced. | ||
Type CA is an enhancement over its predecessor, Type [[C|53/54C]], adding ADDED mode to the A, B, CHOPPED, ALT repertoire. | |||
The "A" in "CA" stands not only for the fact that it is a modified, enhanced replacement, but also because the feature added was "ADDED". | |||
Type CA | Type CA was [[introduced in 1959]] and discontinued in 1973, making it not only the most-produced but also one of the longest-lived. | ||
discontinued in 1973, making it not only the most-produced but | |||
also one of the longest-lived. | |||
Late versions have [[BNC connector]]s instead of [[UHF connector]]s. | Late versions have [[BNC connector]]s instead of [[UHF connector]]s. | ||
Line 34: | Line 30: | ||
[[Lavoie Laboratories]] produced an unauthorized clone, the [[Lavoie LA-265-CA]]. | [[Lavoie Laboratories]] produced an unauthorized clone, the [[Lavoie LA-265-CA]]. | ||
{{MissingSpecs}} | |||
[[ | The risetime of a Type [[545]] oscilloscope with a Type CA plug-in is 15 nanoseconds, and the bandwidth is 24 MHz. | ||
Maximum vertical sensitivity is 50 mV/div. | |||
==Pictures== | ==Pictures== |
Revision as of 09:03, 13 August 2021
Template:Plugin Sidebar 2 The Tektronix Type CA is the most common plug-in for 500-series scopes – over 50,000 were produced.
Type CA is an enhancement over its predecessor, Type 53/54C, adding ADDED mode to the A, B, CHOPPED, ALT repertoire. The "A" in "CA" stands not only for the fact that it is a modified, enhanced replacement, but also because the feature added was "ADDED".
Type CA was introduced in 1959 and discontinued in 1973, making it not only the most-produced but also one of the longest-lived.
Late versions have BNC connectors instead of UHF connectors.
Lavoie Laboratories produced an unauthorized clone, the Lavoie LA-265-CA.
Key Specifications
- please add
The risetime of a Type 545 oscilloscope with a Type CA plug-in is 15 nanoseconds, and the bandwidth is 24 MHz. Maximum vertical sensitivity is 50 mV/div.
Pictures
-
Front view
-
front view
-
left view
-
right view
-
top view
-
bottom view
-
schematic
-