The '''Tektronix 291 Diode Switching Time Tester Power Supply''' was [[introduced in 1963]]. The 291 uses the [[TF-1|TF-1 test fixture]]. | The '''Tektronix 291 Diode Switching Time Tester Power Supply''' was [[introduced in 1963]]. The 291 uses the [[TF-1|TF-1 test fixture]]. |
Revision as of 10:32, 20 August 2021
The Tektronix 291 Diode Switching Time Tester Power Supply was introduced in 1963. The 291 uses the TF-1 test fixture.
TF-1 fixtures have been known to have issues with bad connections with the diode. In at least one case, a TF-1 has been made to work reliably by replacing the weak AlNiCo magnet that holds the axial leaded (magnetic) diode in place, by replacing it with a much stronger FeNdB magnet the same size (easily available on Ebay).