Revision as of 10:32, 20 August 2021

Tektronix 291
Diode Switching Time Tester
Tek 291 front

Produced from 1962 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 291 Diode Switching Time Tester Power Supply was introduced in 1963. The 291 uses the TF-1 test fixture.

TF-1 fixtures have been known to have issues with bad connections with the diode. In at least one case, a TF-1 has been made to work reliably by replacing the weak AlNiCo magnet that holds the axial leaded (magnetic) diode in place, by replacing it with a much stronger FeNdB magnet the same size (easily available on Ebay).

Pictures