P6420: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
(added pictures) |
||
Line 3: | Line 3: | ||
|model=P6420 | |model=P6420 | ||
|summary=RF demodulator probe | |summary=RF demodulator probe | ||
|image= | |image=P6420_0.jpg | ||
|caption= | |caption= | ||
|for=1 MΩ scope inputs | |for=1 MΩ scope inputs | ||
Line 28: | Line 28: | ||
* [[Media:Tekscope_1977_V9_N2.pdf | TekScope 1977 V.9 No.2]] | * [[Media:Tekscope_1977_V9_N2.pdf | TekScope 1977 V.9 No.2]] | ||
* [http://www.barrytech.com/tektronix/probes/tekp6420.html P6420 @ barrytech.com] | * [http://www.barrytech.com/tektronix/probes/tekp6420.html P6420 @ barrytech.com] | ||
==Pictures== | |||
<gallery> | |||
P6420_0.jpg |P6420 probe with [[013-0097-01]] retractable hook tip | |||
P6420_1.jpg |P6420 probe without tip | |||
P6420 Internal DiodeSide.jpg |Internal view diodes | |||
P6420 Internal ResSide.jpg |Internal view input capacitor | |||
</gallery> | |||
[[Category:Demodulator probes]] | [[Category:Demodulator probes]] |
Revision as of 09:58, 28 August 2021
The Tektronix P6420 is an RF demodulator probe for DMMs with 10 MΩ input resistance, providing a DC output voltage proportional to the RMS value of a sine-wave input.
Designed to be used with a digital multimeter with a 10 MΩ input resistance, the P6420 can also be used with oscilloscopes which have a 1 MΩ input for relative flatness readings.
Key Specifications
Frequency range | 10 kHz to 1 GHz (±3 dB), 50 kHz to 500 MHz (±1.5 dB), 100 kHz to 300 MHz (±0.5 dB) |
---|---|
Voltage Range | 0.5 to 24 VRMS (70 Vp-p) |
AC to DC Transfer Ratio Accuracy | ±10% from 0.5 to 5 VRMS between +15 and 35 °C |
Input Capacitance | 3.7 pF |
Maximum Input Voltage | 42.4 V (peak AC + DC) |
Links
Pictures
-
P6420 probe with 013-0097-01 retractable hook tip
-
P6420 probe without tip
-
Internal view diodes
-
Internal view input capacitor