AA501: Difference between revisions

From TekWiki
Jump to navigation Jump to search
mNo edit summary
No edit summary
Line 2: Line 2:
|designers=Bruce Hofer
|designers=Bruce Hofer
|manuals=
|manuals=
*[[Media:AA501-PS501-PS503A.pdf|Tektronix PS501, PS503A, and AA501 Specifications (PDF)]]
* [[Media:070-2958-00.pdf|Tektronix AA501 Instruction Manual]] (PDF)
* [[Media:070-6592-00.pdf|Tektronix AA501A Instruction Manual]] (PDF)
* [[Media:AA501-PS501-PS503A.pdf|Tektronix PS501, PS503A, and AA501 Specifications (PDF)]]
}}
}}
It provides automated measurement of THD+N and levels (RMS responding) in the range of 10 Hz to 100 kHz. Harmonics are measured up to 300 kHz. It has four built-in weighting filters and allows the user to loop an external filter in. Option 01 adds intermodulation measurement. Input impedance is 100 kΩ unlike other analyzers with usually 1 MΩ or near-infinite input impedance. Internal THD in the audio band is specified as typically <−95 dB (0.0018 %). Residual THD+N is specified as <−90 dB (<0.0032 %).
It provides automated measurement of THD+N and levels (RMS responding) in the range of 10 Hz to 100 kHz. Harmonics are measured up to 300 kHz. It has four built-in weighting filters and allows the user to loop an external filter in. Option 01 adds intermodulation measurement. Input impedance is 100 kΩ unlike other analyzers with usually 1 MΩ or near-infinite input impedance. Internal THD in the audio band is specified as typically <−95 dB (0.0018 %). Residual THD+N is specified as <−90 dB (<0.0032 %).
Line 21: Line 23:
Tektronix-AA501-HP239A.JPG|Measuring distortion of an HP239A
Tektronix-AA501-HP239A.JPG|Measuring distortion of an HP239A
</gallery>
</gallery>
[[Category:Manual_needed]]

Revision as of 04:40, 3 October 2021

Tektronix AA501
audio analyzer
Tektronix AA501

Produced from 1980 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix AA501 is a audio analyzer plug-in for the TM500 system.

It provides automated measurement of THD+N and levels (RMS responding) in the range of 10 Hz to 100 kHz. Harmonics are measured up to 300 kHz. It has four built-in weighting filters and allows the user to loop an external filter in. Option 01 adds intermodulation measurement. Input impedance is 100 kΩ unlike other analyzers with usually 1 MΩ or near-infinite input impedance. Internal THD in the audio band is specified as typically <−95 dB (0.0018 %). Residual THD+N is specified as <−90 dB (<0.0032 %).

It was one of the first, if not the first, audio analyzers capable of fully automatic measurements without requiring manual reference level setting, range selection or frequency fine-tuning. It is ideally combined with the SG505 low distortion oscillator.

The AA501 is two slots wide.

Key Specifications

  • please add

Links

Pictures