AA501: Difference between revisions
mNo edit summary |
No edit summary |
||
Line 2: | Line 2: | ||
|designers=Bruce Hofer | |designers=Bruce Hofer | ||
|manuals= | |manuals= | ||
*[[Media:AA501-PS501-PS503A.pdf|Tektronix PS501, PS503A, and AA501 Specifications (PDF)]] | * [[Media:070-2958-00.pdf|Tektronix AA501 Instruction Manual]] (PDF) | ||
* [[Media:070-6592-00.pdf|Tektronix AA501A Instruction Manual]] (PDF) | |||
* [[Media:AA501-PS501-PS503A.pdf|Tektronix PS501, PS503A, and AA501 Specifications (PDF)]] | |||
}} | }} | ||
It provides automated measurement of THD+N and levels (RMS responding) in the range of 10 Hz to 100 kHz. Harmonics are measured up to 300 kHz. It has four built-in weighting filters and allows the user to loop an external filter in. Option 01 adds intermodulation measurement. Input impedance is 100 kΩ unlike other analyzers with usually 1 MΩ or near-infinite input impedance. Internal THD in the audio band is specified as typically <−95 dB (0.0018 %). Residual THD+N is specified as <−90 dB (<0.0032 %). | It provides automated measurement of THD+N and levels (RMS responding) in the range of 10 Hz to 100 kHz. Harmonics are measured up to 300 kHz. It has four built-in weighting filters and allows the user to loop an external filter in. Option 01 adds intermodulation measurement. Input impedance is 100 kΩ unlike other analyzers with usually 1 MΩ or near-infinite input impedance. Internal THD in the audio band is specified as typically <−95 dB (0.0018 %). Residual THD+N is specified as <−90 dB (<0.0032 %). | ||
Line 21: | Line 23: | ||
Tektronix-AA501-HP239A.JPG|Measuring distortion of an HP239A | Tektronix-AA501-HP239A.JPG|Measuring distortion of an HP239A | ||
</gallery> | </gallery> | ||
Revision as of 04:40, 3 October 2021
The Tektronix AA501 is a audio analyzer plug-in for the TM500 system.
It provides automated measurement of THD+N and levels (RMS responding) in the range of 10 Hz to 100 kHz. Harmonics are measured up to 300 kHz. It has four built-in weighting filters and allows the user to loop an external filter in. Option 01 adds intermodulation measurement. Input impedance is 100 kΩ unlike other analyzers with usually 1 MΩ or near-infinite input impedance. Internal THD in the audio band is specified as typically <−95 dB (0.0018 %). Residual THD+N is specified as <−90 dB (<0.0032 %).
It was one of the first, if not the first, audio analyzers capable of fully automatic measurements without requiring manual reference level setting, range selection or frequency fine-tuning. It is ideally combined with the SG505 low distortion oscillator.
The AA501 is two slots wide.
Key Specifications
- please add
Links
- Bruce Hofer, Automatic Distortion Analyzer Speeds Distortion Measurements in Tekscope V.12 No.3 1980 p.14+
Pictures
-
-
Measuring distortion of an SG502
-
Measuring distortion of an HP239A