AM511: Difference between revisions
Jump to navigation
Jump to search
m (→top: clean up, replaced: manuals= → designers= |manuals=) |
mNo edit summary |
||
Line 9: | Line 9: | ||
| designers= |manuals=[[Media:070-2043-00.pdf|Tektronix AM511 Manual (PDF)]] | | designers= |manuals=[[Media:070-2043-00.pdf|Tektronix AM511 Manual (PDF)]] | ||
}} | }} | ||
It is designed to operate as an accessory for the [[7L12]] and [[7L13]] Spectrum Analyzers, | It is designed to operate as an accessory for the [[7L12]] and [[7L13]] Spectrum Analyzers, | ||
intended for measuring-signal-to noise, radiation, and field intensity on CATV, television, | intended for measuring-signal-to noise, radiation, and field intensity on CATV, television, | ||
Line 18: | Line 17: | ||
{{Spec | Frequency Range | 30 to 890 MHz }} | {{Spec | Frequency Range | 30 to 890 MHz }} | ||
{{Spec | Input Impedance | 75 Ω }} | {{Spec | Input Impedance | 75 Ω }} | ||
{{Spec | VSWR | <2:1 }} | {{Spec | VSWR | <2:1 }} | ||
{{Spec | Reference Level | +79 dBmV to 0 dBmV in 1 dB steps }} | {{Spec | Reference Level | +79 dBmV to 0 dBmV in 1 dB steps }} | ||
{{Spec | Output | to Spectrum Analyzer set to −30 dBm, 50 Ω }} | {{Spec | Output | to Spectrum Analyzer set to −30 dBm, 50 Ω }} | ||
{{Spec | Intermodulation | >70 dB down}} | {{Spec | Intermodulation | >70 dB down}} | ||
{{Spec | Calibrator | +30 dBmV, 50 MHz, 75 Ω }} | {{Spec | Calibrator | +30 dBmV, 50 MHz, 75 Ω }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
Revision as of 08:21, 28 October 2021
The Tektronix AM511 is a CATV pre-amplifier plug-in for the TM500 system.
It is designed to operate as an accessory for the 7L12 and 7L13 Spectrum Analyzers, intended for measuring-signal-to noise, radiation, and field intensity on CATV, television, and FM installations. Other uses include radio-system servicing and measurements, as well as increasing sensitivity for EMI measurements. There is a very similar 7k plugin, the 7K11.
Key Specifications
Frequency Range | 30 to 890 MHz |
---|---|
Input Impedance | 75 Ω |
VSWR | <2:1 |
Reference Level | +79 dBmV to 0 dBmV in 1 dB steps |
Output | to Spectrum Analyzer set to −30 dBm, 50 Ω |
Intermodulation | >70 dB down |
Calibrator | +30 dBmV, 50 MHz, 75 Ω |
Links
- Tekscope Vol. 8 No. 2 1976: New Products
Pictures
-
-
AM511 description in 1976 Tek catalog
-
-