P6112: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 17: | Line 17: | ||
{{Spec | Bandwidth | DC to 100 MHz (TDS 220) / DC to 60 MHz (TDS 210) }} | {{Spec | Bandwidth | DC to 100 MHz (TDS 220) / DC to 60 MHz (TDS 210) }} | ||
{{Spec | Risetime | 3.5 ns (TDS 220) / 5.8 ns (TDS 210) }} | {{Spec | Risetime | 3.5 ns (TDS 220) / 5.8 ns (TDS 210) }} | ||
{{Spec | Attenuation | {{Spec | Attenuation | 10× ± 2% at DC (DC coupled system) }} | ||
{{Spec | Maximum input | {{Spec | Maximum input | 300 V<sub>RMS</sub> (Cat I and II) }} | ||
{{Spec | Input impedance | 10 MΩ ± 1.5% // 11.8 pF to 14.8 pF (13.3 pF typ.) }} | {{Spec | Input impedance | 10 MΩ ± 1.5% // 11.8 pF to 14.8 pF (13.3 pF typ.) }} | ||
{{Spec | Compensation range | 15 pF to 35 pF }} | {{Spec | Compensation range | 15 pF to 35 pF }} |
Revision as of 09:02, 21 January 2022
The Tektronix P6112 is a 100 MHz, 10x passive probe intended for the TDS 200 series.
Key Specifications
Bandwidth | DC to 100 MHz (TDS 220) / DC to 60 MHz (TDS 210) |
---|---|
Risetime | 3.5 ns (TDS 220) / 5.8 ns (TDS 210) |
Attenuation | 10× ± 2% at DC (DC coupled system) |
Maximum input | 300 VRMS (Cat I and II) |
Input impedance | 10 MΩ ± 1.5% // 11.8 pF to 14.8 pF (13.3 pF typ.) |
Compensation range | 15 pF to 35 pF |
Cable length | 2 meters (74.7") |
Pictures
-
Package Front
-
Package Rear