AWG615: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Created page, added all info.)
 
No edit summary
Line 11: Line 11:
|designers=
|designers=
|manuals=
|manuals=
* [[Media:071-1512-02.pdf|AWG615 User Manual 071-1512-02]] (PDF)
* [[Media:071-1512-02.pdf|AWG615 User Manual 071-1512-02]]
* [[Media:071-1513-00.pdf|AWG615 Programmer Manual 071-1513-00]] (PDF)
* [[Media:071-1513-00.pdf|AWG615 Programmer Manual 071-1513-00]]
* [[Media:071-1516-01.pdf|AWG615 Service Manual 071-1516-01]] (PDF)
* [[Media:071-1516-01.pdf|AWG615 Service Manual 071-1516-01]]
* [[Media:76W_12991_3-final.pdf|AWG615 Sales Brochure]] (PDF)
* [[Media:071-1516-00.pdf|AWG615 Service Manual 071-1516-00]]
* [[Media:76W_12991_3-final.pdf|AWG615 Sales Brochure]]
}}
}}
The '''Sony/Tektronix AWG615''' is a 1.35 GHz, 2.7 GS/s arbitrary waveform generator.
The '''Sony/Tektronix AWG615''' is a 1.35 GHz, 2.7 GS/s arbitrary waveform generator.
Line 46: Line 47:
* 10 - 256 MByte Flash Disk (replaces Hard disk)  
* 10 - 256 MByte Flash Disk (replaces Hard disk)  
* 1R - Rackmount
* 1R - Rackmount
==Service==
* C3 - Calibration service 3 years
* C5 - Calibration service 5 years
* D1 - Calibration data report
* D3 - Calibration data report 3 years (with Opt. C3)
* D5 - Calibration data report 53 years (with Opt. C5)
* R3 - Repair service 3 years
* R5 - Repair service 5 years
==Recommended Accessories==
* Service Manual - 071-1516-xx
* Protective Cover - 200-3696-01
==Power Plug Options==
* A0 - North American power cord
* A1 - Universal European power cord
* A2 - UK power cord
* A3 - Australian power cord
* A5 - Switzerland power cord
* A6 - Japan power cord
* A10 - China power cord
* A99 - No power cord or AC adapter
==Language Option==
* L0 - English manuals
* L5 - Japanese manuals


==Optional Accessories==
==Optional Accessories==
Line 128: Line 102:
[[Category:Arbitrary waveform generators]]
[[Category:Arbitrary waveform generators]]
[[Category:GPIB interface]]
[[Category:GPIB interface]]
[[Category:Introduced in (?)]]

Revision as of 07:10, 15 October 2022

Sony/Tektronix AWG615
arbitrary waveform generator
Sony/Tektronix AWG615

Produced from (?) to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Sony/Tektronix AWG615 is a 1.35 GHz, 2.7 GS/s arbitrary waveform generator.

Key Specifications

Sampling rate 2.7 GS/s
Resolution 8 bit
Memory 32 M
Output 1 channel, 2 Vp-p into 50 Ω

Software

Standard Accessory Floppy Disks

Firmware

Options

  • 01 - 64.8M points waveform memory
  • 02 - Extends analog bandwidth to 2 GHz
  • 10 - 256 MByte Flash Disk (replaces Hard disk)
  • 1R - Rackmount

Optional Accessories

  • 071-1516-XX - Service Manual
  • 200-3696-01 - Front Cover
  • 020-2556-XX - Rack Mount Kit (for field conversion)
  • 012-0991-00 - GPIB cable
  • 012-1342-00 - BNC cable, 50 Ω
  • 012-1256-00 - BNC cable, 50 Ω, double-shield
  • 011-0049-02 - BNC terminator, 50 Ω
  • 015-0660-00 - BNC power divider, 50 Ω, DC to 300 MHz, VSWR: 1.2 max.
  • 174-1427-00 - SMA cable, 50 Ω, 0.5m, (1.64 ft), male-male
  • 174-1341-00 - SMA cable, 50 Ω, 1.0m, (3.28 ft), male-male
  • 174-1428-00 - SMA cable, 50 Ω, 1.5m, (4.92 ft), male-male
  • 015-0562-00 - SMA precision delay cable, 1ns, male-male
  • 015-0561-00 - SMA precision delay cable, 2ns, male-male
  • 015-1016-00 - SMA precision delay cable, 5ns, male-male
  • 015-1022-00 - SMA terminator, male
  • 015-1014-00 - SMA 50 Ω divider, male
  • 015-0554-00 - SMA-BNC adapter, male-female
  • 015-0572-00 - SMA-BNC adapter, female-male
  • 020-1693-00 - SMA adapter kit
  • 015-0659-00 - BNC low pass filter, 400 MHz
  • 015-0658-00 - BNC low pass filter, 200 MHz
  • 015-0657-00 - BNC low pass filter, 100 MHz
  • CT1 - AC current probe CT-1
  • CT2 - AC current probe CT-2
  • CT3 - AC current probe CT-3
  • K475 - Cart

Standard Accessories

  • 071-1512-xx - User Manual
  • 071-1513-xx - Programmer Manual
  • 063-3779-XX - Sample waveform floppy disk, 3.5 inch
  • 063-A258-XX - Sample program floppy disk, 3.5 inch
  • 063-3780-XX - Performance check/adjustment floppy disk 3.5 inch
  • 063-3763-XX - Arb-Express Software Package
  • 061-4288-XX - Arb-Express Software Package, Instructions
  • 015-1022-01 - SMA 50 Ω terminator, male (2 installed on instrument)
  • Power Cord (except A99)